Munsch MAK-32 Скачать руководство пользователя страница 5

 
 

 

 

 

MEK-32 / MAK-32 

Issue 12.2009/Rev. 02 

Page 5/20 

 

 

2.3  Risks resulting from non-observance of the 

safety instructions 

Non-observance of the safety instructions may cause 
hazards to persons and the environment or damage 
to the hand extruder. Moreover, failure to observe 
the safety instructions may lead to the forfeiture of 
any damages. 
 
Non-observance of the safety instructions may in 
particular
 involve the following risks: 
 

  failure of important hand extruder functions, 

  hazards to persons due to electrical and 

mechanical impacts including risk of burns, 

  hazards to the environment due to vapour-phase 

hazardous substances, 

  risk of fire. 

 
2.4  Safe working practices 
The safety instructions given in these operating 
instructions, the applicable national accident 
prevention regulations and any existing in-company 
work instructions, operating and safety procedures 
issued by the Operator must be followed. 
 
2.5  Safety instructions for Operator / operating 

personnel  

  Before placing the hand extruder in service, 

check the mains voltage and frequency against 
the data indicated on the type tag. The allowable 
tolerances are ± 5 % for voltage and/or 

±

2 % for 

frequency. 

  According to VDE 0100 §55, the hand extruder 

must be operated via a residual current-operated 
circuit breaker or an isolating transformer. 

  CAUTION During hand extruder operation (under 

load), a voltage of not less than 230 V

1)

 must be 

available at the connector of the hand extruder.  

  When using an extension cable, make sure to 

observe the minimum conductor cross-section. 
Use extension cables with protective conductor 
only. 
 

Length 

[m] 

Minimum cross-section  

[mm²] 

up to 19 

4.0 

1)

 

20-50 

6.0 

1)

 

2.1  Identification of information in the operating 

instructions 

In these operating instructions, safety instructions 
whose non-observance may cause hazards to 
persons are identified with 
 

 

 

 

 
Hazard symbol according to DIN 4844 – W 9 
 
for general hazards and with   
 

 

   

 

 
Hazard symbol according to DIN 4844 – W 8 
 
for electrical hazards.  
 
Safety instructions whose non-observance may 
cause damage to the hand extruder and its functions 
are marked with 
 

 

   

CAUTION  

 
 
 
Instructions directly indicated on the hand extruder 
must be strictly followed and kept in a fully legible 
state. 
 
 
2.2  Personnel qualification and training 
The operating, maintenance and inspection 
personnel must possess appropriate qualification for 
the work to be performed. Functional and technical 
responsibilities and supervision of the operating 
personnel must be clearly regulated by the Operator.  
Where the personnel do not have the necessary 
skills and knowledge they must be trained and 
instructed (e.g. a DVS basic welder training in 
extrusion welding). A detailed instruction into hand 
extruder operation will be provided by the 
Manufacturer/Supplier on request. Furthermore, the 
Operator has to make sure that the contents of the 
operating instructions is fully understood by the 
operating personnel. 

 

1)  for 230 V AC 

Содержание MAK-32

Страница 1: ...erial No ______________ Article No ______________ These operating instructions contain important information to be observed for hand extruder operation and maintenance It is therefore imperative that...

Страница 2: ...NG 7 2 7 UNAUTHORIZED MODIFICATIONS AND SPARE PARTS 7 3 TRANSPORT AND STORAGE 8 3 1 TRANSPORT 8 3 2 STORAGE 8 3 3 RETURN TO MUNSCH 8 4 PRODUCT DESCRIPTION 8 4 1 APPLICATION RANGE 8 4 2 GENERAL 8 5 STA...

Страница 3: ...ed standards or parts of these standards were applied DIN EN ISO 12100 1 2004 DIN EN 13732 1 2008 DIN EN ISO 12100 2 2004 In addition the hand extruders are in accordance with the following EC directi...

Страница 4: ...failure to observe the safety instructions may lead to the forfeiture of any damages Non observance of the safety instructions may in particular involve the following risks failure of important hand e...

Страница 5: ...not less than 230 V 1 must be available at the connector of the hand extruder When using an extension cable make sure to observe the minimum conductor cross section Use extension cables with protecti...

Страница 6: ...risk of hand extruder damage When using an external air source make sure that the air supply line is adequately dimensioned CAUTION The supply air must be clean dry and free from oil and water The ha...

Страница 7: ...ction and mounting activities are performed by authorized and qualified personnel who are thoroughly familiar with the operating instructions As a rule the hand extruder must be shut off and the conne...

Страница 8: ...e place Protect the hand extruder from unauthorized access Special preservation is not required 3 3 Return to Munsch Should it become necessary to return the hand extruder to MUNSCH Kunststoff Schwei...

Страница 9: ...mperature can be matched to the weld thickness 5 Startup and Shutoff 5 1 General In addition to the operating instructions and the national and local accident prevention regulations applicable at the...

Страница 10: ...tire joint width at as low a hot air temperature as possible For larger weld seam widths a wider preheat nozzle is available as an accessory 5 3 Starting the hand extruder Observe section Safety CAUTI...

Страница 11: ...elding rod 5 4 2 Replacement and aging of welding rod If the welding rod is to be replaced make sure that any remaining rod in the hand extruder is completely removed For this purpose operate the preh...

Страница 12: ...e to switch off the heating circuits Pull mains connector Maintain the air supply of the hand extruder until the unit has completely cooled down Never use water or another coolant to accelerate the co...

Страница 13: ...MEK 32 MAK 32 Issue 12 2009 Rev 02 Page 13 20...

Страница 14: ...safety risk are prohibited Activities other than those described in this section may only be performed at the Manufacturer s workshops 6 1 Maintenance inspection of MEK MAK hand extruder CAUTION After...

Страница 15: ...MEK 32 MAK 32 Issue 12 2009 Rev 02 Page 15 20...

Страница 16: ...ture 2 3 4 8 10 18 22 14 Melt temperature below setpoint temperature 2 3 9 11 14 Extruder does not heat up 2 3 12 22 Temperature above preset range 2 3 18 19 Controller fault signal E 2 Controller fau...

Страница 17: ...voltage permissible voltage Check mains voltage Rated voltage permissible voltage Check mains voltage 1 15 Extension cable heats up Unroll cable reel Check cable cross section see also section Safety...

Страница 18: ...ol 230 V AC with speed control Extruder heating system 32 650 W 230 V 32 650 W 230 V Air preheater 2100 W 230 V 2300 W 230 V Air supply External air source Integrated air supply Air rate 300 l min at...

Страница 19: ...free from defects in materials and workmanship from the date of its first acquisition Should deficiencies resulting from defects in materials or workmanship be identified during the warranty period t...

Страница 20: ...the Purchaser may demand annulment cancellation of the contract or a price reduction reduction of compensation in lieu of remedial work In such a case the Purchaser shall not be entitled to any replac...