The following Hybrid Management Sub-Layer (HMS) Management Information Bases (MIBs) are standardized
documents present by the Society of Telecommunications Engineers (SCTE) for use with Hybrid Fiber Coax
Outside Plant Status Monitoring. These MIBs must be
used with the user’s choice of Network Management
Software (NMS) when interfacing any transponders or additional equipment provisioned in the HFC plant. The
EB1s transponders are compatible with a variety of NMS packages including Continuity and Cheetah XD. The
following list is described in further detail and is available for download from
www.scte.org
.
SCTE HMS ALARMS MIB: reference HMS028R6 (SCTE 36)
SCTE HMS COMMON MIB: reference HMS024R14
SCTE HMS FIBERNODE: reference HMS025R13
SCTE HMS PROPERTY MIB: reference HMS026R16 (SCTE 38-1)
SCTE HMS PS MIB: reference HMS027R12
SCTE ROOT MIB: reference HMS028R6 (SCTE 36)
SCTE HMS GEN MIB: reference HMS033R10 (SCTE 38-6-2005)
SCTE HMS TIB MIB: reference HMS055R5 (SCTE 38-7)
SCTE HMS DOWNLOAD MIB: reference HMS063R6 (SCTE 38-8)
SCTE HMS TREE MIB: reference HMS072R10
2.2 EB1s Series Product
Features
All models have 63/89 VAC
output; reconfigurable. Factory set for 89 VAC output. Some models
offer a 75 VAC output tap.
Serial status monitoring provided, compatible with HMS-022 protocol.
High efficiency for economical line operation and longer run time from battery input.
Ferroresonant output: filters and regulates load power.
Liquid Crystal Display (LCD) for local visual monitoring.
High input power factor, typically 0.9 or better (line mode).
Wide AC input voltage range. Highly tolerant of spurious noise and low voltage conditions appearing
on the AC power line.
Temperature compensated battery charger with battery temperature sensor.
Robust inverter circuits. Convection cooling eliminates need for forced-air cooling.
Certified UPS product per IEC Standard 60950-1.
Complies with EMI/RFI limits of Standards EN 55022 and EN 55024.
Hot-swap inverter module: field replaceable without interrupting power to the load.
2.3 Unpacking and Inspection
Before installing this equipment,
inspect the power supply for shipping damage or missing components. If the
power supply or other items were damaged in shipment, file a damage claim with the shipping company and
contact your Multilink representative immediately. Be sure to retain the original shipping carton and all packing
material for the power supply until you are certain that warranty return will not be required.
All EB1s Series UPS power supplies include:
Power supply, ready for installation in cabinet
Power cable
Battery temperature sensor cable
Installation and operating instructions
2.4 Missing
or
Damaged
Items
If items are found to be damaged or missing, contact the shipping company and your Multilink representative
immediately. All damage claims must be filed with the shipping company conveying your equipment. Your
Multilink representative will be able to assist with immediate equipment needs if necessary.
Содержание EB1s
Страница 2: ......
Страница 35: ...33 Issue 13 11 14 2017 Fig 8 1 Battery Balancer wiring 36V 3 batteries 1 string ...
Страница 36: ...34 Issue 13 11 14 2017 Fig 8 2 Battery Balancer wiring 48V 4 batteries 1 string ...
Страница 37: ...35 Issue 13 11 14 2017 Fig 8 3 Battery Balancer wiring 36V 6 batteries 2 strings ...
Страница 38: ...36 Issue 13 11 14 2017 Fig 8 4 Battery Balancer wiring 48V 8 batteries 2 strings ...