The Multicom range will send ‘pending
alarms’ (Event type 6) with test reports,
you may need to include pending alarm
QRWLÀFDWLRQVWRFRPHWRWKHRSHUDWRU
*
7KLVÀHOGLV
not used by the Multicom 4 Plus
but may
be used by other products in the Multicom range.
Event
CID Offset (Zone)
Description
Tamper
18
X
950999
00
External Tamper Triggered
Zone 1
18
X
950999
01
Zone 1 Triggered
Zone 2
18
X
950999
02
Zone 2 Triggered
Zone 3
18
X
950999
03
Zone 3 Triggered
Zone 4
18
X
950999
04
Zone 4 Triggered
PSTN Fault Alarm *
18
X
950999
05
PSTN voltage has been lower than the
programmed voltage for the programmed time
Battery Fault Alarm *
18
X
950999
06
The battery voltage has been outside 'normal
operating limits' for the programmed period of
time
GSM Fault Alarm
18
X
950999
07
GSM has not been connected to the network for
the programmed period of time
You will need to have your monitoring station map
the following events for the account (Fax this list) if
Multicom is not already in their Contact ID list.
X = Event, Restore or Previous Alarm (E,R or P)�