background image

Multibor - Suite technology 

The quality and the speed of performance of the procedures depend 

both on the skills of a master and on the correct combination of the 

equipment and materials as well as on the output power of the 

milling cutter, the shapes and sharpness of the caps, the tool rotation 

speed, and the pressure on the nail plate or the foot of a client. The 

Multibor-Suite technology combines the technical capabilities of the 

equipment, the specifics of usage of the tools for machine-assisted 

nail care, the present-day requirements of a client, and the skills of a 

master.  Your milling cutter operates according to the Multibor-Suite 

technology in the Program Mode. This enables you to use the table 

for correct operation of the device in accordance with a pre-selected 

program for a specific procedure. The processor will further 

automatically select the required speed, the output power, and the 

torque, and it will also supervise and control all required changes in 

the course of the operation, smoothly adapting to your manner of 

performing the procedure. 

The additional opportunities of Multibor-Suite 

It is only the MULTIBOR Suite Podolog device family that has two 

control channels and two connections for two engines, which can be 

controlled in turns. This feature would for instance be useful for 

chiropodists. 

Thru the usage of the additional engine of the NAIL type jointly with 

the "Natural Nail" or "Pedicure" programs, it can select the operating 

modes for complex podiatric cases. 

Besides, MULTIBOR Company can supply the Podolog-type devices 

with additional therapeutic engines required for the operation with 

the Omnicut heads under the mechanical nail care technology with 

cuticles trimmed. 

Attention! 

The Omnicut head is not included in the package.

This tool should be purchased separately. 

18

Program Control Mode "Programs"

Press the 'M-button' to select operation modes under the preset 

programs. 

While in the 'Programs' mode, the display shows a character to 

indicate a specific program and a digit to indicate the program's 

number. 

Select a desired program by rotating the Manipulator. 

Press the center of the Manipulator for one time to start the rotation. 

Attention! 

The rpm rates and the programs cannot be changed on 

the go. Stop the rotation to change a program. While a program is in 

operation, it is only possible to change the rotational direction by 

pressing the center of the Manipulator for two times at a run same as 

you double-click on a computer mouse. 

Very important! 

Follow the safety precautions!  

It is allowed to unlock the clamp or to change a tool only after the 

rotation is fully stopped.  

Program H6 

“Reverse” - OFF

Program P7

“Reverse” - ON

Содержание Podolog

Страница 1: ...Professional Station Professional Station Professional Station...

Страница 2: ...a corn callus Lateral nail folds soft abrading Final foot polish Removing of corns and rough skin on toes On the edge of step cracks treatment For a basic step s cracks treatment Rough skin intensive...

Страница 3: ...in the entire device or in separate parts thereof and absence of its components as well as damaged or burnt engine or its power cable shall deprive the User of the opportunity of free repair and shall...

Страница 4: ...deling and correction of artificial nails The lineup of devices comprises the following models Multibor Podolog Multibor Podolog MAX These models have different technical properties and configurations...

Страница 5: ...ified in this User Guide Do not try to use the Milling Cutter is a manner not specified in this document Do not try to use the Milling Cutter for operations not specified in this document Delivery Set...

Страница 6: ...ny items onto them The connection cable remains under big workload while in use therefore it would quickly break down if used improperly e g knots and loops in the cable constant bending at sharp angl...

Страница 7: ...technical ATTENTION It is prohibited to disassemble or modify any components of the Milling Cutter Several parts of the power unit bear high voltage It is not allowed to perform any maintenance proce...

Страница 8: ...Magic Button switch Thru the Multiobr Click Click hereinafter the Manipulator it is possible to switch the rotation on or off increase or decrease the rotation speed change the rotational direction Re...

Страница 9: ...block unit The unit looks like a ball pen conveniently sitting in one s hand and making it possible to easily set and use the standard tools The manufacturer supplies the handheld milling cutters cert...

Страница 10: ...of unbalanced tools vibration while operating the handheld milling cutter results in the loss of the warranty rights for the user Changing the tools 1 Switch off the tool rotation 2 Wait until the too...

Страница 11: ...s an intermediate position 4 Click twice until locked in 5 Extract the old tool 6 Set the new tool into the clamp 7 Turn the clamp lock into the B direction over two clicks Pedal The pedal is intended...

Страница 12: ...et into the relevant inlet 4 Check if there is a tool or a standard temporary cover in the collet clamp of the handheld milling cutter 5 Never forget to make sure that the collet clamp is locked and t...

Страница 13: ...his will activate the self test of the Milling Cutter and it will be indicated in the form of running lights at the LED Range and in the form of running eights at the Display As the running eights fad...

Страница 14: ...nd broken down or destroyed In order to fix the problem caused by such a signal the following steps must be taken 1 Remove the foreign items from the surface of the pedal 2 Press the pedal a few times...

Страница 15: ...means of a relevant combination of characters digits and segments and is also backed up by specific audible signals In any mode prior to switching on the tool rotation its direction is shown by an arr...

Страница 16: ...alance of a tool have significant influence on the vibration of the milling cutter There is a risk of damaging a tool at the speeds exceeding 30 000 rpm The milling cutter has two levels of rotation a...

Страница 17: ...e rpm rate rotate the Manipulator counterclockwise 4 To alter the rotational direction the reverse function press the center of the Manipulator twice at a run same as you double click on a computer mo...

Страница 18: ...for one time to start the rotation Attention The rpm rates and the programs cannot be changed on the go Stop the rotation to change a program While a program is in operation it is only possible to ch...

Страница 19: ...procedure The processor will further automatically select the required speed the output power and the torque and it will also supervise and control all required changes in the course of the operation...

Страница 20: ...power applied When the nail care master approaches the permitted limits of the output power in the course of work the power control processor sends an audible warning signal The nail care master shou...

Страница 21: ...ct program Program Mode 4 Select the correct tool any of the modes 5 Resume the operation In the event of the micromotor overheating switch off the Milling Cutter for 30 minutes and then resume the op...

Страница 22: ...e rotation Attention The pedal only reacts to closure and opening of the electric contacts No changes occur to the rotation speed of a tool Maintenance Very important All types of preventive maintenan...

Страница 23: ...the collet clamp 4 Resume the operation No Motor 1 Check the connection of the motor 2 Please refer to the Service Center Pedal is out of order 1 Remove the foreign items from the surface of the pedal...

Страница 24: ......

Отзывы:

Похожие инструкции для Podolog