Before getting started, please read this User Guide carefully. 

Attention! 

The device has sufficient means of electronic protection, 

but no automation is able to provide 100% safety against unjustified, 

inept or destructive steps by the User. 

Please remember! 

Before you switch on the rotation, make sure that 

nothing stands in its way, the engine is free, there is a tool in the 

collet clamp, the collet clamp is locked, and the collet holds the tool 

firmly.

  

Caution! 

Mechanical defects in the entire device or in separate parts 

thereof and absence of its components as well as damaged or burnt 

engine or its power cable shall deprive the User of the opportunity of 

free repair and shall not impose any warranty obligations upon the 

Manufacturer. 

Please handle the device with due care and use it as prescribed. Do 

not allow for excessive workload and do not use it for operations the 

device is not intended for, and it will then serve you very well for 

years! 

Should you have any questions regarding the use of the device or 

should you put the device into such modes of operation where from 

you don't know the way out, please contact the Service Center. 

Service Center

www.multibor.eu

2

Please note the following:

The progrms for “MULTIBOR Pedicure Bits” and program for the “Pedicure” are different. If you work with replaceable sand caps 
based on rubber or with

 

sintered cersmics, please select the “Pedicure” only. If you try to activate the “MULTIBOR Pedicure Bits”, 

there is a risk that your tool bends or breaks down/

Carbide ball  o2 mm

Removal of a corn callus

Lateral nail folds soft abrading

Final foot polish

Removing of corns and rough skin on toes

On the edge of step cracks treatment

For a basic step's cracks treatment

Rough skin intensive abrading

Very rough heels primary treatment

Abrasive, silicone,  max   o9 mm

For toes abrading

Abrasive, silicone,  max   o13 mm

The step's skin grinding

Silicone, max  o10 mm

The natural nail polishing

Diamond cylinder, max  o5 mm

Lateral nail folds

Diamond flame, max  o3.3 mm

Removal of pterygium

Diamond ball,  max  o3.3 mm

Eponychium treatment

Tool

Name

Display

Type

Содержание Podolog

Страница 1: ...Professional Station Professional Station Professional Station...

Страница 2: ...a corn callus Lateral nail folds soft abrading Final foot polish Removing of corns and rough skin on toes On the edge of step cracks treatment For a basic step s cracks treatment Rough skin intensive...

Страница 3: ...in the entire device or in separate parts thereof and absence of its components as well as damaged or burnt engine or its power cable shall deprive the User of the opportunity of free repair and shall...

Страница 4: ...deling and correction of artificial nails The lineup of devices comprises the following models Multibor Podolog Multibor Podolog MAX These models have different technical properties and configurations...

Страница 5: ...ified in this User Guide Do not try to use the Milling Cutter is a manner not specified in this document Do not try to use the Milling Cutter for operations not specified in this document Delivery Set...

Страница 6: ...ny items onto them The connection cable remains under big workload while in use therefore it would quickly break down if used improperly e g knots and loops in the cable constant bending at sharp angl...

Страница 7: ...technical ATTENTION It is prohibited to disassemble or modify any components of the Milling Cutter Several parts of the power unit bear high voltage It is not allowed to perform any maintenance proce...

Страница 8: ...Magic Button switch Thru the Multiobr Click Click hereinafter the Manipulator it is possible to switch the rotation on or off increase or decrease the rotation speed change the rotational direction Re...

Страница 9: ...block unit The unit looks like a ball pen conveniently sitting in one s hand and making it possible to easily set and use the standard tools The manufacturer supplies the handheld milling cutters cert...

Страница 10: ...of unbalanced tools vibration while operating the handheld milling cutter results in the loss of the warranty rights for the user Changing the tools 1 Switch off the tool rotation 2 Wait until the too...

Страница 11: ...s an intermediate position 4 Click twice until locked in 5 Extract the old tool 6 Set the new tool into the clamp 7 Turn the clamp lock into the B direction over two clicks Pedal The pedal is intended...

Страница 12: ...et into the relevant inlet 4 Check if there is a tool or a standard temporary cover in the collet clamp of the handheld milling cutter 5 Never forget to make sure that the collet clamp is locked and t...

Страница 13: ...his will activate the self test of the Milling Cutter and it will be indicated in the form of running lights at the LED Range and in the form of running eights at the Display As the running eights fad...

Страница 14: ...nd broken down or destroyed In order to fix the problem caused by such a signal the following steps must be taken 1 Remove the foreign items from the surface of the pedal 2 Press the pedal a few times...

Страница 15: ...means of a relevant combination of characters digits and segments and is also backed up by specific audible signals In any mode prior to switching on the tool rotation its direction is shown by an arr...

Страница 16: ...alance of a tool have significant influence on the vibration of the milling cutter There is a risk of damaging a tool at the speeds exceeding 30 000 rpm The milling cutter has two levels of rotation a...

Страница 17: ...e rpm rate rotate the Manipulator counterclockwise 4 To alter the rotational direction the reverse function press the center of the Manipulator twice at a run same as you double click on a computer mo...

Страница 18: ...for one time to start the rotation Attention The rpm rates and the programs cannot be changed on the go Stop the rotation to change a program While a program is in operation it is only possible to ch...

Страница 19: ...procedure The processor will further automatically select the required speed the output power and the torque and it will also supervise and control all required changes in the course of the operation...

Страница 20: ...power applied When the nail care master approaches the permitted limits of the output power in the course of work the power control processor sends an audible warning signal The nail care master shou...

Страница 21: ...ct program Program Mode 4 Select the correct tool any of the modes 5 Resume the operation In the event of the micromotor overheating switch off the Milling Cutter for 30 minutes and then resume the op...

Страница 22: ...e rotation Attention The pedal only reacts to closure and opening of the electric contacts No changes occur to the rotation speed of a tool Maintenance Very important All types of preventive maintenan...

Страница 23: ...the collet clamp 4 Resume the operation No Motor 1 Check the connection of the motor 2 Please refer to the Service Center Pedal is out of order 1 Remove the foreign items from the surface of the pedal...

Страница 24: ......

Отзывы:

Похожие инструкции для Podolog