"Sensors" menu - configuration and calibration
Carrying out calibration
8
30252060-02-EN
V2.20161017
35
⇨
One of the following screens appears:
Calibration was successful.
⇨
OR
Calibration was not successful. In the example, the fill level at calibration point 02 is lower
than at calibration point 01.
In this case, you must check the values entered and correct them manually.
22.
Press:
⇨
You have completed automatic calibration.
Entering calibration values manually
You can input calibration values manually if you have already carried out automatic calibration on an
identical tank and know the fill level at each float height.
To save time, you can enter the individual values without filling the tank.
During the manual input process you will see the following screen:
Overview of calibration points with fill levels and float heights
8.5.3