1044 – AL Inj. Drift Limit 1 Cyl. B3
Cause
Corrective action
The drift correction for
energization (start and duration)
of injector B3 has violated limit 1.
The injector has soon reached its
maximum drift limit.
u
Schedule an injector replacement.
1045 – AL Inj. Drift Limit 1 Cyl. B4
Cause
Corrective action
The drift correction for
energization (start and duration)
of injector B4 has violated limit 1.
The injector has soon reached its
maximum drift limit.
u
Schedule an injector replacement.
1046 – AL Inj. Drift Limit 1 Cyl. B5
Cause
Corrective action
The drift correction for
energization (start and duration)
of injector B5 has violated limit 1.
The injector has soon reached its
maximum drift limit.
u
Schedule an injector replacement.
1047 – AL Inj. Drift Limit 1 Cyl. B6
Cause
Corrective action
The drift correction for
energization (start and duration)
of injector B6 has violated limit 1.
The injector has soon reached its
maximum drift limit.
u
Schedule an injector replacement.
1048 – AL Inj. Drift Limit 1 Cyl. B7
Cause
Corrective action
The drift correction for
energization (start and duration)
of injector B7 has violated limit 1.
The injector has soon reached its
maximum drift limit.
u
Schedule an injector replacement.
1049 – AL Inj. Drift Limit 1 Cyl. B8
Cause
Corrective action
The drift correction for
energization (start and duration)
of injector B8 has violated limit 1.
The injector has soon reached its
maximum drift limit.
u
Schedule an injector replacement.