RAW WATER CIRCUIT (open circuit)
Number of cylinders
8
Raw water pump: Inlet pressure, min.
L
bar
-0.2
Raw water pump: Inlet pressure, max.
L
bar
+0.5
Pressure loss in external raw water system, max.
L
bar
1.0
LUBE OIL SYSTEM
Number of cylinders
8
Lube-oil operating temperature before engine, from
R
°C
75
Lube oil operating temperature before engine, to
R
°C
80
Lube oil operating pressure before engine, from
R
bar
5.6
Lube oil operating pressure before engine, to
R
bar
6.1
Lube oil operating pressure (low idle) (meas. point: before engine)
R
bar
2.0
FUEL SYSTEM
Number of cylinders
8
Fuel pressure at engine supply connection, min. (when engine is starting)
L
bar
-0.3
Fuel pressure at supply connection to engine, min. (when engine is running)
L
bar
-0.3
Fuel pressure at engine supply connection, max. (when engine is starting)
L
bar
+0.5
Fuel supply flow, max.
R
liter/min
1.6
GENERAL OPERATING DATA
Number of cylinders
8
Firing speed, from
R
rpm
100
Firing speed, to
R
rpm
120
STARTING (electric)
Number of cylinders
8
Starter, rated voltage (standard design)
R
V=
24
STARTING SYSTEM (with air/hydraulic starter motor)
Number of cylinders
8
Starting air pressure before starter motor, min.
R
bar
18*
Starting air pressure before starter motor, max.
R
bar
30
CAPACITIES
Number of cylinders
8
Engine coolant, engine-side (with cooler)
R
liter
70*
Engine oil at initial filling (standard oil system) (Option: max. operating inclina-
tions)
R
liter
65
Oil change quantity, max. (standard oil system) (Option: max. operating incli-
nations)
R
liter
60
MS150031/06E 2016-010
| Technical Data | 49
TIM-ID: 0000011003 - 001