4.3 Putting the engine into operation after scheduled out-of-
service period
Preconditions
☑
Engine is stopped and starting disabled.
Putting into operation
Item
Action
Lube oil system
Check engine oil level (→ Page 192).
Coolant circuit
Check coolant level (→ Page 205).
Coolant circuit
Preheat coolant with preheating unit.
Fuel prefilter
Battery-charging generator
drive
Check condition of drive belt (→ Page 212)
Engine Control System
Switch master switch to ON;
Press illuminated pushbutton READY FOR OPERATION (→ Page 110).
LOP
Press illuminated pushbutton LAMP TEST (→ Page 110).
MS150031/06E 2016-010
| Operation | 113
TIM-ID: 0000002684 - 004