
6.18 Battery-Charging Generator
6.18.1 Battery-charging generator drive – Coupling condition check
Preconditions
☑
Engine is stopped and starting disabled.
Battery-charging generator drive
– Coupling condition check
1.
Remove screws (1).
2.
Remove protective cover (2).
3.
Check resilient coupling (3) for cracks and
plastic deformation.
4.
If there is serious deformation or crack for-
mation, contact Service.
5.
Install protective cover (2) with screws (1).
MS150068/01E 2014-01
| Task Description | 251
TIM-ID: 0000007390 - 008
Содержание 12 V 4000 M23F
Страница 3: ...Commissioning Note ...
Страница 4: ......
Страница 233: ...Coolant drain point engine free end 1 Drain point MS150068 01E 2014 01 Task Description 233 TIM ID 0000014545 004 ...