268 – SD Spinning Value
ZKP-Number: 2.8006.591
Skid signal error
Yellow alarm; warning
Cause
Corrective action
Analog skid signal faulty.
Short circuit or wire break.
1. Check sensor and wiring, replace as necessary (→ Page 265).
2. Fault is rectified when engine is restarted (→ Page 77).
3. Contact Service.
269 – SD Loadp.Analog filt.
ZKP-Number: 2.8006.588
Load pulse analog signal faulty
Yellow alarm; warning
Cause
Corrective action
The filtered analog signal from
the load pulse is not present.
Short circuit or wire break.
1. Check wiring, replace as necessary (→ Page 265).
2. Fault is rectified when engine is restarted (→ Page 77).
3. Contact Service.
270 – SD Frequency Input
ZKP-Number: 2.8006.590
Signal error, frequency input
Red alarm; forced idle
Cause
Corrective action
Frequency input faulty.
Short circuit or wire break.
1. Check wiring (→ Page 265).
2. Check speed demand transmitter.
3. Contact Service.
301 – AL Timing Cylinder A1
ZKP-Number: 1.8004.500
Time-of-flight measuring fault of injector
Cause
Corrective action
Flight time value extremely low
or extremely high.
u
Replace injector if the fault message appears frequently
(→ Page 179).
302 – AL Timing Cylinder A2
ZKP-Number: 1.8004.501
Time-of-flight measuring fault of injector
Cause
Corrective action
Flight time value extremely low
or extremely high.
u
Replace injector if the fault message appears frequently
(→ Page 179).