596 – AL Test Parameters
ZKP-Number: 1.8004.645
Yellow alarm; warning
Cause
Corrective action
The parameter set is used for
trials. The alarm remains set
until a series parameter set is
loaded.
u
Contact Service.
600 – SD T-Exhaust A+B
ZKP-Number: 1.8004.646
Signal error, exhaust temperature sensor A- and B-side
Yellow alarm; warning
Cause
Corrective action
Exhaust temperature sensor on
A- and B-side faulty.
Short circuit or wire break.
1. Check sensor and wiring, replace as necessary (→ Page 265).
2. Contact Service.
601 – SD ETC1+ETC2
ZKP-Number: 1.3011.227
Signal error, ETC speed sensor 1 and 2
Yellow alarm; warning
Cause
Corrective action
ETC speed sensors 1 and 2
faulty.
Short circuit or wire break.
1. Check sensor and wiring, replace as necessary (→ Page 265).
2. Contact Service.
602 – AL CAN Engine Start Lock
ZKP-Number: 2.1090.930
Start interlock from plant pending
Yellow alarm; warning
Cause
Corrective action
Start interlock initiated by plant.
u
The alarm is reset by canceling the engine start instruction or
the CAN request.
158 | Troubleshooting | MS150068/01E 2014-01
TIM-ID: 0000045495 - 001
Содержание 12 V 4000 M23F
Страница 3: ...Commissioning Note ...
Страница 4: ......
Страница 233: ...Coolant drain point engine free end 1 Drain point MS150068 01E 2014 01 Task Description 233 TIM ID 0000014545 004 ...