Number of cylinders
12
12
16
18
Cooling system: conditioned water
x
x
x
x
Direction of rotation: c.c.w. (facing driving
end)
x
x
x
x
Number of cylinders
12
12
16
18
Cylinder configuration: V angle
Degrees
90
90
90
90
Bore
mm
130
130
130
130
Stroke
mm
150
150
150
150
Displacement per cylinder
liters
1.99
1.99
1.99
1.99
Displacement, total
liters
23.88
23.88
31.84
35.82
Compression ratio
16
16
16
16
Cylinder heads: single-cylinder
x
x
x
x
Cylinder liners: wet, replaceable
x
x
x
x
Inlet valves per cylinder
2
2
2
2
Exhaust valves per cylinder
2
2
2
2
Standard flywheel housing flange (engine
main PTO)
SAE
0
0
0
0
Flywheel interface
DISC
18"
18"
18"
18"
COMBUSTION AIR / EXHAUST GAS
Number of cylinders
12
12
16
18
Charge air pressure before cylinder - DL
R
bar abs
2.3
2.5
2.5
2.4
COOLANT SYSTEM (HT circuit)
Number of cylinders
12
12
16
18
Coolant temperature (at engine connec-
tion: outlet to cooling equipment)
A
°C
95
95
95
95
Coolant temperature after engine, alarm
R
°C
97
97
97
97
Coolant temperature after engine, shut-
down
L
°C
102
102
102
102
Coolant antifreeze content, max.
L
%
50
50
50
50
Pressure loss in off-engine cooling sys-
tem, max.
L
bar
0.7
0.7
0.7
0.7
COOLANT SYSTEM (LT circuit)
Number of cylinders
12
12
16
18
Coolant temperature before intercooler
(at engine inlet from cooling equipment)
A
°C
55
55
55
55
Coolant antifreeze content, max.
L
%
50
50
50
50
Pressure loss in off-engine cooling sys-
tem, max.
L
bar
0.7
0.7
0.7
0.7
MS15018/02E 2013-09
| Technical Data | 25
TIM-ID: 0000010846 - 001