Maintenance
Series 505G2 SilentFlo™ Hydraulic Power Unit
63
Prerequisite
You will need a filter element (MTS part number 100-009-495) or a filter kit (MTS part number 100-
030-195).
Procedure
To change the filter element:
Note:
The dirty-filter indicator may light when the HPU is first started due to low hydraulic fluid
temperature. When the HPU is at normal operating temperature, recheck the indicator to
determine if the element actually needs replacement.
1. Turn off the HPU.
2. Open the top of the HPU with an 8-mm (5/16-inch) allen wrench.
Return Line Filter Component Identification
3. Check the output pressure gage. Ensure that the pressure is at zero before proceeding.
4. Unscrew the filter cover. The filter element, bypass assembly, and filter bowl can be removed
as one assembly. Be careful not to spill any hydraulic fluid.
5. Remove the disposable element from the bowl. Discard any fluid contained in the filter bowl.
6. Wipe out any remaining sludge in the filter housing with a lint-free cloth.
7. Inspect the O-rings in the manifold for any sign of deterioration. If necessary, replace the
defective O-ring(s).
8. Insert a new filter element into the bowl and reinstall the bowl assembly. Align the 90° elbow
outlet at the bottom of the assembly such that it directs hydraulic fluid flow towards the side of
the reservoir as shown in the following illustration. Screw the filter cover back on.
Содержание SilentFlo 505G2 Series
Страница 1: ...Series 505G2 SilentFlo Hydraulic Power Unit Model 505G2 07 Model 505G2 11 100 227 350 C ...
Страница 31: ...Installation Series 505G2 SilentFlo Hydraulic Power Unit 31 Installation Install the HPU 32 HPU Setup 35 ...
Страница 39: ...Operation Series 505G2 SilentFlo Hydraulic Power Unit 39 Operation Operator s Panel 40 ...
Страница 70: ......
Страница 79: ...Accessories Series 505G2 SilentFlo Hydraulic Power Unit 79 Caster Kit ...
Страница 80: ......
Страница 90: ...Appendix B Declaration of Conformity 90 Series 505G2 SilentFlo Hydraulic Power Unit Example ...
Страница 91: ...Appendix B Declaration of Conformity Series 505G2 SilentFlo Hydraulic Power Unit 91 ...
Страница 92: ......
Страница 93: ......