Introduction
Series 505G2 SilentFlo™ Hydraulic Power Unit
17
Item Component
Description
8
Filler Cap
Vents the hydraulic fluid reservoir. This is where you add
hydraulic fluid.
9
Reservoir
Holds the hydraulic fluid and houses the hydraulic pump and
motor. The surge suppressor (optional) is mounted to the
pump.
10
Hydraulic and Water
Connections
Connection points for the hydraulic fluid distribution system,
water source, and return lines.
11
Water Flow Regulator
Sets the amount of water flowing through the heat
exchanger. Adjust the water flow to regulate the temperature
of the hydraulic fluid.
12
Drain Valve
Drains the hydraulic fluid from the reservoir.
13
High Pressure Filter
Location
The high pressure filter is optional. If provided, it would be
located where indicated in the figure.
14
Output Pressure
Control
Sets the output pressure of the HPU.
15
Heat Exchanger
Cools the hydraulic fluid by using an oil-to-water heat
exchanger. The heat exchanger removes most of the heat
generated by the HPU.
16
Temperature Gage
Displays the temperature of the hydraulic fluid.
17
Return Filter
Filters particles out of the hydraulic fluid as it is returned to
the HPU.
18
Power Disconnect
Switch
Disconnects the incoming power from the HPU. The switch
is a lockable, mechanical latch. Power is removed whenever
the door to the electrical enclosure is open (the switch is in
the off position). However, incoming power lines to the
switch are live unless power is removed externally. The
power disconnect switch is located on the front panel of the
electrical enclosure (item 5).
Содержание SilentFlo 505G2 Series
Страница 1: ...Series 505G2 SilentFlo Hydraulic Power Unit Model 505G2 07 Model 505G2 11 100 227 350 C ...
Страница 31: ...Installation Series 505G2 SilentFlo Hydraulic Power Unit 31 Installation Install the HPU 32 HPU Setup 35 ...
Страница 39: ...Operation Series 505G2 SilentFlo Hydraulic Power Unit 39 Operation Operator s Panel 40 ...
Страница 70: ......
Страница 79: ...Accessories Series 505G2 SilentFlo Hydraulic Power Unit 79 Caster Kit ...
Страница 80: ......
Страница 90: ...Appendix B Declaration of Conformity 90 Series 505G2 SilentFlo Hydraulic Power Unit Example ...
Страница 91: ...Appendix B Declaration of Conformity Series 505G2 SilentFlo Hydraulic Power Unit 91 ...
Страница 92: ......
Страница 93: ......