background image

ProtoSmoke™ Unit Operation

This diesel locomotive contains a Proto-Sound® 2.0 controlled smoke unit that 
outputs smoke through the smokestack on the roof  of  the engine.  The smoke unit 
is essentially a small heating element and wick that soaks up and then heats a 
mineral oil-based fluid that emits smoke.  The smoke is then forced out of  the 
stack by a small electric fan.  Smoke volume is controlled by the Proto-Sound® 2.0 
system.

With a few easy maintenance steps, you should enjoy trouble-free smoke unit 
operation for years.

When preparing to run this engine, add 15-20 drops of  smoke fluid through the 
smokestack (see below).  We recommend M.T.H. ProtoSmoke™ fluid.  Do not 
overfill the unit or the fluid may leak out and coat the interior engine components.

To adjust the amount of  smoke produced, turn the smoke unit volume control 
clockwise to increase the amount of  smoke, or counter-clockwise to reduce the 
amount.

If  you choose not to add smoke fluid (or have already added fluid but choose to 
run smoke-free), turn off  the smoke unit by turning the smoke unit control to the 
“OFF” position, fully Counter Clockwise position. 

Failure either to add fluid to 

the smoke unit or to turn it off  may damage the smoke unit heating element 
and/or wicking material.

When the smoke output while running the engine begins to diminish, add another 
10-15 drops of  smoke fluid or turn the smoke unit off.

When storing the unit for long periods of  time, you may want to add about 15 
drops of  fluid to prevent the wick from drying out.

Premier 

Diesel Engine with PS-2 and Proto-Scale 3-2

18

3GS-21B GenSet 

Running the engine without a primed 
smoke unit may cause damage

Adding Smoke Fluid

Add Smoke Fluid

Opened Smokestack lid

Closed Smokestack lid

Make sure that the smokestack lid is open before adding the smoke fluid.  You only
need to add smoke fluid to one of  the two smokestacks nearest the cab. 

Содержание Premier 3GS-21B GenSet

Страница 1: ...Gauge track system including M T H s RealTrax or ScaleTrax or traditional tubular track It is also compatible with most standard AC transformers See page 24 for a complete list of compatible transfor...

Страница 2: ...of the following patents 6 019 289 6 280 278 6 281 606 6 291 263 6 457 681 6 491 263 6 604 641 6 619 594 6 624 537 6 655 640 2010 M T H Electric Trains Columbia MD 21046 CAUTION ELECTRICALLY OPERATED...

Страница 3: ...se only a drop or two on each pivot point Checking the Battery You may find if your locomotive was built several months before you set it up that the rechargeable battery has run down and needs to be...

Страница 4: ...OFF position fully Counter Clockwise position Failure either to add fluid to the smoke unit or to turn it off may damage the smoke unit heating element and or wicking material Premier Diesel Engine w...

Страница 5: ...or 2 Rail track operation please do the following 1 Remove the center rail pickup roller assemblies 2 Change the power input from 3 Rail to 2 Rail as seen in the figure below Premier Diesel Engine wit...

Страница 6: ...polarity for 2 rail operations will result in the locomotive starting in reverse instead of forward or not receiving the DCS signal Should this occur it is not necessary to swap the wires from the tra...

Страница 7: ...he speed you set after you release the throttle until you turn it again to change the voltage and speed Bell To sound the bell in an engine equipped with a bell firmly press and release the Bell butto...

Страница 8: ...s made by this engine turn the manual volume control shown below clockwise to increase the volume and counter clockwise to decrease the volume Premier Diesel Engine with PS 2 and Proto Scale 3 2 8 3GS...

Страница 9: ...YS PSA quickly but firmly tap the Bell button once followed by 2 quick taps of the Horn Whistle button while the engine is moving Tap the buttons quickly but allow approximately second between each pr...

Страница 10: ...high voltage level once you have stopped the engine to run the FYS PSA Otherwise the engine without FYS PSA will begin vibrating on the track as its motors strain to move the train since they cannot...

Страница 11: ...ngine in neutral then quickly tap the transformer s horn whistle button one time then quickly tap the Bell button two times allowing approximately second to lapse between each quick button press Repea...

Страница 12: ...wo horn whistle blasts will indicate that the engine has made the change Automatic Sounds Certain Proto Sound 2 0 sound effects automatically play in programmed conventional mode conditions Squealing...

Страница 13: ...y and should not need additional grease until after 50 hours of operation or one year whichever comes first Remove the two grease port screws two per gearbox Use a grease tube dispenser and put a smal...

Страница 14: ...he rails of the track turning the rag frequently to ensure that you are using clean cloth on the rails Thereafter keep an eye on the track and clean it when it gets dirty to ensure good electrical con...

Страница 15: ...ry away any remains 4 Slip the new tire onto the wheel You may find it useful to use two small flathead screwdrivers to stretch the tire over the wheel 5 If you twist the tire while stretching it over...

Страница 16: ...out light bulb s Carefully remove bulb s from mounting Disconnect light bulb harness from main harness wire Replacement bulb harnesses are available directly from the M T H Parts department Order onl...

Страница 17: ...recharged There are a number of ways you can do this Leave the engine in neutral with track voltage at 10 12 volts for 6 7 hours so the battery can fully recharge if your engine has a smoke unit be s...

Страница 18: ...increase the amount of smoke or counter clockwise to reduce the amount If you choose not to add smoke fluid or have already added fluid but choose to run smoke free turn off the smoke unit by turning...

Страница 19: ...kly discolored and hard it should be replaced Replacement parts and wick replacement instructions are available directly from the M T H Parts Department Order online www mth railking com e mail parts...

Страница 20: ...he bell button The bell won t work on a separate bell button When I try to fire the coupler FYS starts The Proto Coupler won t let the engine uncouple on the fly The coupler does not fire or stay coup...

Страница 21: ...dom intervals The engine is locked into the neutral position Follow the procedure in the Lock into a Direction section Engine speed must be below 10 scale mph approx 10 volts or less in conventional m...

Страница 22: ...effects can be as realistic as possible Proto Sound 2 0 disables the reversing unit whenever FYS PSA is enabled This way the engine remains still at its stop as the operator cycles through the FYS PS...

Страница 23: ...gency Stop Single button push stops all Proto Sound 2 0 trains but does not turn off the power One Touch Global Mute UnMute Single button mutes or unmutes all DCS controlled locomotives user defined a...

Страница 24: ...3 Lionel LW Powermaster U A U A U A 8 17v 8 18v 8 18v 60 Watt 75 Watt 135VA Standard Standard Electronic All Trol Left Terminal Right Terminal 0 24v 300 Watt Electronic Dallee Hostler Left Terminal Ri...

Страница 25: ...lies Proto Sound 2 0 is designed to work with most standard DC power supplies and AC transformers The following charts lists the recommended DC and AC transformers Note that many of the AC operational...

Страница 26: ...he description regardless of whether you discussed the problem with a service technician when contacting the Service Center for your Return Authorization Please make sure you have followed the instruc...

Отзывы: