background image

Premier 

Diesel Engine with PS-2 and Proto-Scale 3-2

10

3GS-21B GenSet 

Fire

Rear

Coupler

=

Bell

+

Sound System Cued to Play 

Freight Yard or Passenger 

Station Sounds (FYS)/(PSA)

Bell

1st

Sequence 

FYS/PSA

+

2nd

Sequence 

FYS/PSA

+

3rd

Sequence 

FYS/PSA

+

4th

Sequence 

FYS/PSA

=

Operator

Controls 

When Bell 

Turns Off

Horn/
Whistle

Horn/
Whistle

Horn/
Whistle

Horn/
Whistle

Horn/
Whistle

!

The FYS/PSA will continue, and within a few seconds, the engine will start and move out 
on its own at the current throttle setting, in the same direction it was traveling when you 
began the sequence.  Once the bell turns off, the operator regains control of  the 
transformer's Bell and 

Horn/Whistle buttons and can ring the bell or blow the 

horn/whistle as usual.

Tips on Using FYS/PSA

!

You can terminate FYS/PSA at any time by turning off  power to the track for 15 

seconds.

!

You do not have to be in Forward to use FYS/PSA.  At the conclusion of  the full 

sequence, the train will pull away from the station in whatever direction you were 
going when you activated the feature.

!

You can use FYS/PSA even if  you are double-heading with another engine. If  the 

second engine is not equipped with Proto-Sound® 2.0, you must remember not to 
leave the throttle at a high voltage level once you have stopped the engine to run the 
FYS/PSA.  Otherwise, the engine without FYS/PSA will begin vibrating on the track 
as its motors strain to move the train, since they cannot be automatically disabled 
during the FYS/PSA cycle (or if  an original Proto-Sound engine, FYS/PSA are 
triggered differently and that engine's motor-disable feature will not be active when 
you run FYS/PSA in Proto-Sound® 2.0).

!

FYS/PSA can be triggered from Neutral.  It will operate the same as if  triggered while 

in motion except that, at the conclusion of  the FYS/PSA, the engine will depart in 
the next direction of  travel, as opposed to the direction it was traveling before 
entering Neutral.

Proto-Coupler  Operation

This locomotive is equipped with one or more coil-wound Proto-Couplers for remote 
uncoupling action.  Because Proto-Couplers are controlled through the Proto-Sound® 2.0 
microprocessor, they do not require an uncoupling track section or modification to your 
layout to function. You can fire a coupler from neutral or while in motion.  Use the code 
shown below (and in the chart on page 7) to fire the coupler(s).

Rear Coupler:

To fire the rear coupler, quickly tap the Bell button once followed by three quick taps of  the 
Horn/Whistle button, allowing approximately ½ second to lapse between each quick button 
press.  The sound of  the liftbar and air line depletion will play, and the knuckle will be 
released.

Содержание Premier 3GS-21B GenSet

Страница 1: ...Gauge track system including M T H s RealTrax or ScaleTrax or traditional tubular track It is also compatible with most standard AC transformers See page 24 for a complete list of compatible transfor...

Страница 2: ...of the following patents 6 019 289 6 280 278 6 281 606 6 291 263 6 457 681 6 491 263 6 604 641 6 619 594 6 624 537 6 655 640 2010 M T H Electric Trains Columbia MD 21046 CAUTION ELECTRICALLY OPERATED...

Страница 3: ...se only a drop or two on each pivot point Checking the Battery You may find if your locomotive was built several months before you set it up that the rechargeable battery has run down and needs to be...

Страница 4: ...OFF position fully Counter Clockwise position Failure either to add fluid to the smoke unit or to turn it off may damage the smoke unit heating element and or wicking material Premier Diesel Engine w...

Страница 5: ...or 2 Rail track operation please do the following 1 Remove the center rail pickup roller assemblies 2 Change the power input from 3 Rail to 2 Rail as seen in the figure below Premier Diesel Engine wit...

Страница 6: ...polarity for 2 rail operations will result in the locomotive starting in reverse instead of forward or not receiving the DCS signal Should this occur it is not necessary to swap the wires from the tra...

Страница 7: ...he speed you set after you release the throttle until you turn it again to change the voltage and speed Bell To sound the bell in an engine equipped with a bell firmly press and release the Bell butto...

Страница 8: ...s made by this engine turn the manual volume control shown below clockwise to increase the volume and counter clockwise to decrease the volume Premier Diesel Engine with PS 2 and Proto Scale 3 2 8 3GS...

Страница 9: ...YS PSA quickly but firmly tap the Bell button once followed by 2 quick taps of the Horn Whistle button while the engine is moving Tap the buttons quickly but allow approximately second between each pr...

Страница 10: ...high voltage level once you have stopped the engine to run the FYS PSA Otherwise the engine without FYS PSA will begin vibrating on the track as its motors strain to move the train since they cannot...

Страница 11: ...ngine in neutral then quickly tap the transformer s horn whistle button one time then quickly tap the Bell button two times allowing approximately second to lapse between each quick button press Repea...

Страница 12: ...wo horn whistle blasts will indicate that the engine has made the change Automatic Sounds Certain Proto Sound 2 0 sound effects automatically play in programmed conventional mode conditions Squealing...

Страница 13: ...y and should not need additional grease until after 50 hours of operation or one year whichever comes first Remove the two grease port screws two per gearbox Use a grease tube dispenser and put a smal...

Страница 14: ...he rails of the track turning the rag frequently to ensure that you are using clean cloth on the rails Thereafter keep an eye on the track and clean it when it gets dirty to ensure good electrical con...

Страница 15: ...ry away any remains 4 Slip the new tire onto the wheel You may find it useful to use two small flathead screwdrivers to stretch the tire over the wheel 5 If you twist the tire while stretching it over...

Страница 16: ...out light bulb s Carefully remove bulb s from mounting Disconnect light bulb harness from main harness wire Replacement bulb harnesses are available directly from the M T H Parts department Order onl...

Страница 17: ...recharged There are a number of ways you can do this Leave the engine in neutral with track voltage at 10 12 volts for 6 7 hours so the battery can fully recharge if your engine has a smoke unit be s...

Страница 18: ...increase the amount of smoke or counter clockwise to reduce the amount If you choose not to add smoke fluid or have already added fluid but choose to run smoke free turn off the smoke unit by turning...

Страница 19: ...kly discolored and hard it should be replaced Replacement parts and wick replacement instructions are available directly from the M T H Parts Department Order online www mth railking com e mail parts...

Страница 20: ...he bell button The bell won t work on a separate bell button When I try to fire the coupler FYS starts The Proto Coupler won t let the engine uncouple on the fly The coupler does not fire or stay coup...

Страница 21: ...dom intervals The engine is locked into the neutral position Follow the procedure in the Lock into a Direction section Engine speed must be below 10 scale mph approx 10 volts or less in conventional m...

Страница 22: ...effects can be as realistic as possible Proto Sound 2 0 disables the reversing unit whenever FYS PSA is enabled This way the engine remains still at its stop as the operator cycles through the FYS PS...

Страница 23: ...gency Stop Single button push stops all Proto Sound 2 0 trains but does not turn off the power One Touch Global Mute UnMute Single button mutes or unmutes all DCS controlled locomotives user defined a...

Страница 24: ...3 Lionel LW Powermaster U A U A U A 8 17v 8 18v 8 18v 60 Watt 75 Watt 135VA Standard Standard Electronic All Trol Left Terminal Right Terminal 0 24v 300 Watt Electronic Dallee Hostler Left Terminal Ri...

Страница 25: ...lies Proto Sound 2 0 is designed to work with most standard DC power supplies and AC transformers The following charts lists the recommended DC and AC transformers Note that many of the AC operational...

Страница 26: ...he description regardless of whether you discussed the problem with a service technician when contacting the Service Center for your Return Authorization Please make sure you have followed the instruc...

Отзывы: