1.

 

Connect the battery to the BAT terminal. Make sure the polarities are 
correctly connected. Sequentially connect the solar panel to SOL terminal 
and connect POE source to PoE input (lower) jack. (If solar panel or PoE 
source is installed before the battery, and if the polarities of the battery be 
reversed, then the battery will be disconnected.) 
 

2.

 

Make sure the battery is properly connected to the unit. If no battery is 
connected, then the voltage at BAT terminal will be approx 27.3V+0.5V 

 

3.

 

The solar panel cannot be used stand alone without battery connected. 

 

4.

 

When a solar panel and PoE input are connected to the charger, if the 
voltage of solar panel is higher than 36V, then solar panel is always the 
main power source of the charger.  

 

5.

 

When charge from solar panel, as the battery full and turn to floating 
stage, the CHA light will start flash.  

 

6.

 

When charge from PoE, as the battery full, the CHA light will be turn off, if 
the CHA is always flash, that means the input wattage lower than the 
required minimum wattage. If only charge battery, the minimum input 
wattage is 30W, if full load, the minimum input wattage is 80W. 

 

7.

 

When battery connect to BAT terminal and with valid voltage, then the 

LOA indicator will always light on even no load connected.

 

 

Содержание SOL10P24 Series

Страница 1: ...Mstronic Co Ltd SOL10P24 Series Solar PoE Charge Controller Gigabit PoE Injector USER S MANUAL...

Страница 2: ...Rail Mountable Support Gigabit Ethernet Applications Remote Power Systems Surveillance Sensors Wireless Station AP Client Repeaters UPS Systems Lighting Fences Gates Protection Battery Polarity Revers...

Страница 3: ...polarity reverse indicator the LED lights when the battery polarities are reversed detail description see Sec 5 1 6 IN PoE Input Jack the lower RJ45 jack used for PoE input Allowed input voltage 36 57...

Страница 4: ...nel cannot be used stand alone without battery connected 4 When a solar panel and PoE input are connected to the charger if the voltage of solar panel is higher than 36V then solar panel is always the...

Страница 5: ...SOL10P24 Series 8 It can be two separate outputs on the rear panel make sure the total draw is not over the limit 9 The V of PoE input Solar input and battery are not the same grounding must be prope...

Страница 6: ...PUT Model No Output 1 at rear terminal Output 2 at front upper RJ45 SOL10P24 24BNN 24V 10A as Bat Volt 24V 1 25A 45 78 regulated SOL10P24 48ANN 24V 10A as Bat Volt 48V 0 625A 12 36 regulated SOL10P24...

Страница 7: ...ion will be disable if there is PoE power sources connected when the battery polarities reversed the battery will be disconnected 5 2 Battery Over Discharge Protection Cuts off the load when the batte...

Страница 8: ...e burnt when battery output current over 15A 5 8 Load Output Voltage Limit The output voltage of the rear terminal is the same as battery 5 91 POE to Battery Charger Voltage Float 26 8V 0 2V Equalize...

Страница 9: ...power Data pair A 3 Vdc BI_DB power Data Pair B Vdc BI_DB power Data Pair B 4 Vdc BI_DC power Data Pair C Vdc BI_DC power Data Pair C 5 Vdc BI_DC power Data Pair C Vdc BI_DC power Data Pair C 6 Vdc BI...

Отзывы: