5.6
Output Short Circuit Protection:
When the rear output terminal or PoE output be short circuit,
protection be active, the product stop output and auto-recover
when the terminal back to normal connection.
5.7
Battery Output Current Limit:
The fuse will be burnt when battery output current over 15A
5.8
Load Output Voltage Limit:
The output voltage of the rear terminal is the same as battery.
5.91
POE to Battery Charger Voltage :
Float = 26.8V ± 0.2V
Equalize = 28.4V ± 0.2V
5.92
SOLAR to Battery Charger Voltage :
charger go to Voltage = 28.8 V ± 0.2V
6.
GENERAL DESCRIPTION
6.1 Operation Temperature: -40 - +60 Degree
6.2 Storage Temperature: -40 - +85 Degree
6.3 Operation Humidity: 5% - 90% non-condensing
6.4 Cooling:
Free air cooling
6.5 SIZE 150*118*40mm (L*W*H)