4.2
Typical Lubrication Schematic
A typical power end and gear reducer lubrication oil schematic is shown below.
ITEM #
DESCRIPTION
1
RESERVOIR, VENTED 50 GALLON MIN CAPACITY
2
SUCTION LINE, PIPE OR HOSE, 1 1/2” ID MINIMUM
3
SUCTION STRAINER, 50 GPM MIN. 300 SQ IN MIN. 40-100 MESH w/3-5 PSI RELIEF
4
CHECK VALVE, SWING, 1 1/2” ID MINIMUM
5
VACUUM GAUGE, LIQUID FILLE, 0-30” Hg
6
PUMP, GEAR TYPE, 20 GPM, 300 PSI MIN. ENGINE OR TRANSMISSION DRIVEN
7
PRESSURE LINE, PIPE OR HOSE, 3/4” ID MINIMUM
8
FILTER, 50 GPM/200 PSI MIN. 25-33 MICRON ELEMENTS, w/ 15-25 PSI RELIEF
9
PRESSURE GAUGE, LIQUID FILLED, 0-200 PSI
10
RELIEF VALVE, ADJUSTABLE, 60-200 PSI, 3/4” ID 20-25 GPM MINIMUM
11
RELIEF RETURN LINE, PIPE OR HOSE, 3/4” ID
12
POSER FRAME DRAIN LINE, PIPE OR HOSE, 3” NPT
13
GEAR REDUCER DRAIN, PIPE OR HOSE, 2”NPT
14
TEMPERATURE TRANSDUCER/ GAUGE, 0-250°F
15
OPTIONAL HEAT EXCHANGER
16
OPTIONAL OIL COOLER
Содержание QI-1000
Страница 7: ...1 20 Drawings Pump Assembly Overall Dimensions All Plunger Sizes TI 600 TRIPLEX...
Страница 8: ...QI 1000 QUINTUPLEX...
Страница 9: ...1 30 Dual Pump Assembly Overall Dimensions 1 30 1 600 HP Dual Pump Assembly Overall Dimensions...
Страница 10: ...1 30 2 1000 HP Dual Pump Assembly Overall Dimensions...
Страница 11: ...1 50 Drawings Gear Reducer Installation Positions 1 50 1 Gear Reducer Position Left Hand...
Страница 12: ...1 50 2 Gear Reducer Position Right Hand...
Страница 22: ...4 6 Lubrication Attachment Points See images below showing lubrication inlet and outlet locations...
Страница 36: ......
Страница 39: ...5 50 Power Frame Crank Rotation NOTE Crank Rotation can either be clockwise or counterclockwise...
Страница 43: ...Fluid End Assembly 3 25 4 50 continued...