Operation and Maintenance
When determining the design of the pump installation, clearance is recommended for inlet and outlet
connections as well as providing for a pressure relief device for the discharge line.
A pressure relief device is
required for all applications of this pump. Failure to implement a pressure relieving device may result
in significant damage to the pump and attached piping, serious injury or death of personnel, and will
void the pump warranty.
Please read the following concerning pressure relief devices and the allowable
mounting locations.
Spring loaded ball and seat relief valves:
Pressure relief devices of this type rely on a ball and seat interface to create a seal. Force is exerted on the ball,
typically with springs, to balance a predetermined line pressure. This type of pressure relief device is not
designed for full opening once relief pressure has been achieved, in other words,
a ball and seat relief valve is
not a full-bore volume relief device and sufficient fluid volume will cause line pressure to continue to rise
due to the small flow area available
. As the line pressure exceeds the set pressure of the relief valve, the ball
temporarily separates from the seat thus allowing excess pressure to flow through. Once line pressure has
dropped below the set pressure of the relief valve, the ball will re-seat. Due to the small volume relief capacity
of these types of pressure relief devices it is acceptable to install them on a fluid end gauge connection(s).
While not intended as a full-bore volume relief device connection point, the gauge connection will provide a
sufficient conduit for a ball and seat type relief valve.
Valves or other closure devices shall not be installed
between the pop-off valve and the fluid end.
Always follow the manufacturer’s recommendations for the
installation, use, and maintenance of the relief valve.
Full bore (pop-off) relief valves:
Full-bore relief valves are designed to allow full bore dissipation of pressure by relieving large volumes of
fluid. As such,
these relief devices must not be installed on the fluid end gauge connection(s).
The pop-off
valve should be installed as close to the fluid end as possible and in the discharge piping circuit at either the
blind side of the fluid end (for single side discharge) or connected to a TEE fitting on the discharge side of the
fluid end.
Valves or other closure devices shall not be installed between the pop-off valve and the fluid
end.
Always follow the manufacturer’s recommendations for the installation, use, and maintenance of the
pop-off valve.
Below are the maximum relief set pressures based on plunger diameter.
Plunger Diameter
Relief Device Maximum Set Pressure
2.75”
15,000 psig
3.00”
15,000 psig
3.25”
11,020 psig
3.50”
11,020 psig
4.00”
8,438 psig
4.50”
6,667 psig
Содержание QI-1000
Страница 7: ...1 20 Drawings Pump Assembly Overall Dimensions All Plunger Sizes TI 600 TRIPLEX...
Страница 8: ...QI 1000 QUINTUPLEX...
Страница 9: ...1 30 Dual Pump Assembly Overall Dimensions 1 30 1 600 HP Dual Pump Assembly Overall Dimensions...
Страница 10: ...1 30 2 1000 HP Dual Pump Assembly Overall Dimensions...
Страница 11: ...1 50 Drawings Gear Reducer Installation Positions 1 50 1 Gear Reducer Position Left Hand...
Страница 12: ...1 50 2 Gear Reducer Position Right Hand...
Страница 22: ...4 6 Lubrication Attachment Points See images below showing lubrication inlet and outlet locations...
Страница 36: ......
Страница 39: ...5 50 Power Frame Crank Rotation NOTE Crank Rotation can either be clockwise or counterclockwise...
Страница 43: ...Fluid End Assembly 3 25 4 50 continued...