1)
With the MSI-3460 on, press the
TARE
key and the
USER
keys
simultaneously.
2)
The LCD shows
. Press
TARE
.
3)
The sub-menu item
StrnG
(String) appears. Press
TARE
.
4)
The current print pode format
number is displayed.
5)
Set up a print format with one or
more digits representing the data
type required for the print output.
In this example, we’ll set the Print format
for a Net, Gross, Tare output with a
carriage return/line feed between each
print output. The number entry required
will be 2349. The 2 is for Net weight,
the 3 for Gross weight, the 4 for Tare
weight, and the 9 inserts a space before
the next print output.
6) Press the
USER
key to scroll
through the digits until the desired
digit is shown, then press
TARE
to enter the digit value. Repeat
for the remaining digits.
7) When the entire number is
displayed press
TARE
. The next
item in the Print menu appears,
Cntrl
.
8) Press
TARE
to enter the print
control menu. The last set control
mode will appear.
9) To change the print control mode,
press
USER
.
In this example, we’ll set the print control
mode to continuous.
10) Press
USER
key until the desired
print control mode is shown.
11) When the desired print mode is
shown, push
TARE
to save. The
next print setup item,
rAte
appears. If you have set
continuous (cont) as your print
control, proceed to step 12). For
any other Control mode jump to
step 15.
12) Press
TARE
to enter the print
rate number entry screen. The
current print rate appears on the
LCD.
In this example, we’ll set the print rate
to an output rate of once every 2
seconds.
Printer / Output Setup
blinking
blinking
fixed
fixed
fixed
&QWUO
Next Print Menu Item
3ULQW
6WUQ
blinking
fixed
blinking
Example Value
blinking
blinking
2))
2))
8V(U
Function Key Prints
Print is disabled
/R$G
&RQW
Function Key Prints
Print is disabled
UDWH
Next Print Menu Item
1= Current Wt
(Wt-Unit-Mode )
2= Net Wt
(Wt-Unit-Net )
3= Gross Wt
(Wt-Unit-Grs )
4= Tare Wt
(Wt-Unit-Tare )
5= Total Wt
(Wt-Unit-Total )
6= Total Count
(#Samples-TCNT )
7= Current Wt
(no units or mode )
8=
(Reserved)
9= CR-LF (
)
TARE
TARE
TARE
TARE
TARE
TARE
TARE
TARE
TARE
USER
F
USER
F
USER
F
USER
F
USER
F
blinking
Example Value
The number represents the print
interval rate in seconds. Use 0 for the
fastest the MSI-8000 can go (~5 times
per second). To set a once a minute
transmission, set the rate to 60. To
set once per hour, set the rate to 3600, etc. Largest possible
entry is 65535 which is >18 hours.
TARE
USER
F
USER
F
USER
F
USER
F
Press Simultaneously
TARE
USER
F
RF Remote Display Option
43
Figure 7-3. Printer Output Setup
Содержание MSI-3460
Страница 1: ...MSI 3460 Challenger 3 Operator s Manual 152161 Rev A...
Страница 2: ......
Страница 57: ...Appendix 53 Notes...
Страница 58: ...54 MSI 3460 Operator s Manual Notes...
Страница 59: ......