6
MSI-3460 Operator’s Manual
1.4 Specifications
Accuracy
±(0.1% +1d). ‘d’ equals one displayable increment.
Resolution
Standard displayed resolution: 2500-3750’d’. Resolutions to
10000’d’ (non LFT units only) are possible. Internal A/D resolution
24 bits.
Standard
Capacities
lb 250 500 1000 2000 5000 10,000 15,000
kg 125 250 500 1000 2500 5000 7500
Power
Battery operated, 6V rechargeable sealed lead acid battery pack
(standard Challenger Charger) Typically 50 hours of battery life with
automatic sleep mode and automatic power off.
Display
Five digit, large 1.5 in (38 mm) numeric red GaAIAs Light Emitting
Diode (LED)
Operating Temp
-40°F to +122°F (-40°C to +50°C), LFT range -10°C to +40°C
Operating Time
50 hours typical/100 hours max. (depends on operating mode)
Enclosure
NEMA 4/IP65 powder coated alodined cast aluminum
Load Cell
Standard 350 Ω Bridge, S-Beam
USER
Programmable multifunction button for use as
TEST, TOTAL, UNIT, PEAK, NET/GROSS, VIEW TOTAL, LEARN
(for RF Remote Control), HI-RES
CAL
Front panel calibration switch (located behind wire sealable screw)
Initiates full digital calibration procedure
Auto Zero
Maintenance
Standard, can be disabled internally
Auto-Off Mode
Prolongs battery life by turning POWER off after 15, 30, 45 or 60
minutes (operator determined) of no scale activity
Auto-Sleep Mode
Prolongs battery life by dimming LED display after 5, 15, or 30
minutes of no activity
Units
kg, lb (other units available with custom calibrations)
Filtering
Selectable: OFF, Low (LO), Medium (HI-1), High (HI-2)
Totalization
Standard: Press button or automatic; TOTAL weight up to 99999 X
1000 kg or lb
Peak
Uses unfiltered faster reading of A/D, (>220 readings per second)
Setpoints
Three internal standard setpoints and three ultra bright LEDs on
front panel
Service Counter
Two independent 32 bit registers; register 1 updated each time
weight exceeds 25% of capacity; register 2 updated each time
weight exceeds overload; when register 1 exceeds 16383 or
register 2 exceeds 1023, display reads “Cnt” for load cell counter;
Test function shows the two readings in order
Construction
All of these features are housed in a single, low-profile, cast
aluminum housing consisting of three sections:
The front of the scale houses the display, controls and all
electronics
The center section contains the load cell, lifting eye and hook
The rear of the scale features a quick access battery compartment
Table 1-1. Specifications