English
tester MS012 COM
4
•
ST1
,
ST2
: output terminals of rotor windings of the simulated alternator to connect to the
terminals of the voltage regulator stator: P, S, STA, Stator.
•
GC
: output terminal to connect voltage regulator terminals: COM, SIG, and others.
•
FR
: load control output terminal to connect to the voltage regulator terminals: FR, DFM, M.
•
F1
,
F2
: rotor output terminals of the simulated alternator to connect to the voltage regulator
brushes or their respective terminals: DF, F, FLD.
5
–
USB
port
: a socket to connect the tester to a computer or a laptop for the purpose of
software update.
The back panel of the tester contains (Fig.2) a terminal for connection of a supply cable 1 and
a safety fuse 2.
Figure 2 – Back view
A set of 10 diagnostic cables is included in the tester set (Fig.3).
Figure 3 - Set of diagnostic cables MS0111
The color marking must be observed when connecting diagnostic cables to the tester terminals.