English
Operation manual
3
1 TESTER DESCRIPTION
The front panel of the tester contains (Fig.1).
Figure 1 - Front view
1
–
LCD display
:
a
sensor screen where information on the voltage regulator is displayed and
through which the tester is controlled.
2
–
Adjustment knobs
: to set up parameters for voltage regulator diagnostics:
•
EL LOAD
: adjustment knob with two functions: 1) to set the required resistance of the simulated
rotor in the main menu; 2) to change the load on the simulated alternator and on the tested
voltage regulator respectively, in the range from 0 to 100%.
•
STATOR
: adjustment knob to change frequency of stator windings displayed as engine rpm in
the range from 0 to 6000.
•
VOLTAGE
: adjustment knob to set the required voltage generated by the voltage regulator.
Cannot be used with terminal mode L/FR.
3
–
ON/OFF
: button to switch the tester ON/OFF.
4
–
Terminals
: output terminals
to connect the diagnostic cables:
•
В
+
: voltage regulator plus (terminal 30 and terminal 15);
•
В
-
: voltage regulator minus (earth, terminal 31);
•
D+
: control lamp terminal used for connection to the voltage regulator terminals: D+, L, IL, 61.