ELECTRICITY SUPPLY
Before connecting this apparatus to the electricity supply, check the information given
on the apparatus rating plate and ensure that;
A) Your supply is single phase A.C. (alternating current) of the stated frequency
with neutral nominally at earth potential.
B) Your supply voltage is within the stated range.
C) The current rating is within the capacity of your outlet.
D) Your plug or electricity supply circuit is fitted with a suitable fuse.
220v - 240v
110v - 120v
Fuse rating
5 amp
see note for 110V - 120V
WARNING! This apparatus must be earthed.
The wires in the mains lead are coloured in accordance with the following code;
220v - 240v
110v - 120v
Live
Brown
Black
Neutral
Blue
White
Earth
Green and Yellow
Green
Connect the wires to a non-reversible 3-pin plug as follows;
Green and Yellow or Green to terminal marked E (Earth), G (Ground), coloured Green
or Green and Yellow or marked with the Earth symbol.
Blue or White wires to terminal marked N (Neutral) or Common or coloured Blue.
Brown or Black wires to terminal marked L (Live) or Phase or coloured Brown.
Note 110v - 120v installations to comply with National and State Wiring Codes.
IMPORTANT Consult an electrician if in any doubt or if your supply system has any of
the following:
No earth.
A coloured code different from the above.
Reversible plugs.
Supply and return leads that are both above earth potential.