![MSE CENTAUR 2 Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/mse/centaur-2/centaur-2_instruction-manual_1846881027.webp)
SERVICING
27
7.3 Adjustment Of Balance Detector
With the centrifuge upright and after operation with a loaded rotor for a few
minutes, to allow the motor to settle in its operating position, insert a 1mm thick
gauge between the microswitch actuator and the side of the tacho-box
(Item 6. Figure 6).
By turning the Balance detector adjusting screw, Item 7, Figure 6 adjust the
microswitch towards the side of the tacho-box until the microswitch just operates
(breaks).
Ensure that the microswitch operates (re-makes) when the gauge is removed.
Содержание CENTAUR 2
Страница 28: ...SERVICING 28 Figure 6 Partially Exploded View Of Centaur 2 ...
Страница 31: ...CIRCUIT DESCRIPTION 31 ...