![MSA General Monitors IR4000S Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/msa/general-monitors-ir4000s/general-monitors-ir4000s_instruction-manual_1846478035.webp)
Model IR4000S
31
9.2 Specifications
9.2.1 Agency
Approvals
CSA
FM
ATEX and IECEx
CE
Marking
SIL 2 suitable
HART
Registered
FM requires the following statement: This Approval does not include or imply Approval of
apparatus to which the subject instrumentation may be connected. In order to maintain
an FM Approved system, the apparatus to which this instrument is connected, must also
be Approved by FM Approvals.
9.2.2 System
Specifications
Area Classification:
CSA/FM
Class I, Division 1, 2 Groups B, C, D and
Class I, Zone 1, IIB+H
2
, T5, Type 4X (Ta = -40°C
to +75°C)
ATEX/IECEx: (SIRA 08ATEX1095X,
SIR 08.0033X)*
Ex db IIB + H
2
, T5 Gb (Ta = -60°C to +75°C)
Ex tb IIIC T100°C Db IP66
*
The applicable compliance standards are listed on the product certificates which can be obtained
via our website
9.2.3 Mechanical
Specifications
Length
6.5 inches (165 mm)
Width
6.0 inches (152 mm)
Height
3.21 inches (82 mm)
Weight
5.5 lbs. (2.5 kg)
Mounting Holes
5.05 inches (128 mm) (center to center)
9.2.4 Electrical
Specifications
Input Power
absolute min (V) 20
nominal (V) 24
absolute max (V) 36
Max. Wattage at 24 VDC (W) 2.0