SFH-50 Quick Start Guide
16
SFH-50 Quick Start Guide
SFH-50
Quick Start Guide
Appendix
1
Troubleshooting
Typical symptoms, causes, and actions
Symptoms or message
on the controller
Cause and/or action
HEAD DID NOT
LOAD
The controller failed to load the operating
system into the head.
Check that all cables are connected, and all
devices have power.
Check the order in which the devices are
powering up. If two devices on the network try
to power up and initialise their Ethernet
connection at the same time, the devices can
conflict with each other on the network. Avoid
powering the head from the power output
socket on the controller, in order to avoid
powering them up simultaneously. Use an
independent power source for each, and power
up the controller after powering up the head.
If you have connected more than one head,
connected the MRMC system to another local
network, or moved the controller and head
between networks, check that correct LAN
addresses have been entered in the controller.
See
Working with Local Area Networks
on page
17.
HEAD NOT LOADED
LOAD FAIL
FAILED TO LOAD
HEAD
FAILED TO
INITIALIZE
ETHERNET
Controls move in the
wrong direction
Change the working direction of the controls
to your preference.
Limits are being
ignored or causing the
head to oscillate when
reached.
The axes have not been zeroed. You must do
this at the beginning of each session just after
you load the head.
Содержание SFH-50
Страница 1: ...Quick Start Guide Document version SFH50 QSG 20150811 Part number MRMC 1166 00 SFH 50 HEAD ...
Страница 4: ...SFH 50 Quick Start Guide iv Appendix 3 Specifications 33 ...
Страница 10: ...SFH 50 Quick Start Guide 6 SFH 50 with Roll Ring Mounting rods LCM Zoom LCM Focus ...
Страница 38: ...SFH 50 Quick Start Guide 34 SFH 50 with Roll Ring 130 53 25 25 40 192 25 25 27 25 max 305 480 455 ...
Страница 39: ...SFH 50 Quick Start Guide 35 188 215 116 Roll Ring inner diameter Platform width Roll Ring platform length ...