background image

3000

6000

9000

11000

13000

16000

18000

20000

500ml×18 clamps

1100W

AC220V

±

22V

 

50Hz

±

1Hz

 

1240mm×777mm×670mm

 

220kg(single unit)

 

0-20%

0.1%

Infrared

95%

0

-

20000LX

9 Levels

5

6

2. Overview

2.3 Specifications

LOM-7450 

           

 

LOM-7450-CO2 

                       

LOM-7450-L 

4

℃~

60

±

0

.

3

℃(

37

℃)

0rpm, 30rpm

300rpm

±

1 rpm

Φ

26mm

6

0

999h

740 500mm

×

1

50ml×90/250ml×30/500ml×18/

1000ml×12/500ml×6

Model

Temperature

Settings Range

Temperature

Control Range

Environmental Condition

Temperature

Control Precision

Temperature uniformity

Rotation Speed

Speed Precision

Oscillation Range

Program Segments

Timer Range

Platform Size

Platform Number

Maximum Capacity

Standard Configuration

Power

Power Supply

Overall Size

Net Weight

 CO

2

Concentration Rang

 CO

2

Concentration Precision

 CO

2

 Detecting sensor

Chamber Humidity

Illuminance

Control Range

Illuminance

Control Levels

Ambient temperature minus 15 °C to 60 °C (lowest 4 °C)

Temperature

Humidity

10

℃~

35

℃  

20

80

%

RH

0.1 °C (in constant temperature state)

-

-

-

-

-
-

-

-

-
-

-

-

2. Overview

Illuminance Levels for models with lighting function:

Illuminance Level

Illuminance (Lx)

Natural Light in Chamber

0

1

2

3

4

5

6

7

8

Remark: 

Listed temperature control range and uniformity are measured when the

 

lighting  function  is  off  for  model 

LOM-7450-L

.  The  lighting  function  of  the  model 

may

 

affect the temperature uniformity and cooling effectiveness.

Содержание IncuShaker LOM-7450-CO2

Страница 1: ...Stackable Incubator Shaker User s Manual Please read this user s manual carefully before using the product LOM 7450 7450 CO2 7450 L...

Страница 2: ...choosing IncuShaker Series Incubator Shaker Your trust and support in MRC LTD are greatly appreciated MRC Incubator Shaker Series is model designed for shaking and heat samples according to the resear...

Страница 3: ...e instruments are running with the maximum load it is recommended to set the rotation speed no more than 250 rpm 11 Please make sure the vent of the instrument is kept away from other vents or heat so...

Страница 4: ...rview 2 2 Features Large view window LCD dot matrix display User friendly interface Multi segment programming Extra long timing up to 999 hours Soft start and smooth acceleration Open door cut off swi...

Страница 5: ...Range Platform Size Platform Number Maximum Capacity Standard Configuration Power Power Supply Overall Size Net Weight CO2 Concentration Rang CO2 Concentration Precision CO2 Detecting sensor Chamber H...

Страница 6: ...X H c Overal size when stacking three units W X D X H 124 78 67cm 124 132 67cm 124 78 200cm Please leave adequate space around the instrument to help the cooling system of the instrument to dissipate...

Страница 7: ...shown in figure 2 It may cause the pipe connect the incubator and the inlet port to fall off and the leak of the CO2 gas if the secondary pressure is too high High CO2 concentration will do harm to yo...

Страница 8: ...tening screws on the flask clamp regularly to prevent it from falling off Please clean the instrument regularly Please check if the v belt at the bottom of the instrument is not loosened after using t...

Страница 9: ...to stop the instrument when it s in Simple Operation or Timing Program mode 9 Settings Turn on the power switch at the right side of the instrument after the instrument is properly placed Thanks for...

Страница 10: ...s after finishing running the program Return to Timing Program page When Timing Program Operation shows on the display window press the button to choose whether to continue running Stoppig Y N Press t...

Страница 11: ...ing Main Interface Press the button to choose a function and enter the button to enter the corresponding operation page a Basic settings Press the button to choose the parameter that needs to be modif...

Страница 12: ...e current parameters and return to the temperature control parameter settings C 2 2 Temperature Calibration The value outside of the bracket is the target temperature value the value inside the bracke...

Страница 13: ...he calibrated value are not saved If press the button in the calibration mode the instrument will exit the CO2 calibration and the target value is not saved and reset to factory settings The instrumen...

Страница 14: ...for more than 5 minutes The alarm indicator light will flash and the buzz will sound The electromagnetic gas valve will be closed automatically Press any key to cancel the alarm status and the instru...

Страница 15: ...t connected Power outlet out of power Power switch off Change to a new fuse with the same specification Position at the powr outlet Position inside the electrical cabinet Remove interference source of...

Страница 16: ...For Model LOM 7450 CO2 only For Model LOM 7450 CO2 only For Model LOM 7450 CO2 only For Model LOM 7450 CO2 only For Model LOM 7450 CO2 only Optional Accessories Name Specifications Name Specifications...

Отзывы: