E3
Installation Instructions and Owner’s Manual
Unvented Liquid Propane Fired Room Heater
DANGER
: Carbon monoxide poisoning may lead to
death.
Carbon Monoxide Poisoning:
Early signs of carbon monoxide poisoning resemble the
flu, with headaches, dizziness, or nausea. If you have
these signs, the heater may not be working properly.
Get fresh air at once! Have heater serviced. Some
people are more affected by carbon monoxide than oth
-
ers. These include pregnant women, persons with heart
or lung disease or anemia, those under the influence of
alcohol, and those at high altitudes.
Propane/LP Gas:
Propoane/LP gas is odorless. An odor making agent is
added to propane/LP gas. The odor helps you detect
a Propane/LP gas leak. However the odor added to
propane/LP gas may be present even though no odor
exists. Make certain you read and understand all warn
-
ings. Keep this manual for reference. It is your guide to
safe and proper operation of this heater.
Product Features
Figure 1
PRECAUTIONS:
1. MHVFBI10LPT may be installed in a bedroom, but
not a bathroom, or any place where a strong wind
would shut down the appliance.
2. This heater needs outside ventilation air to run
properly. The Oxygen Depletion Sensor (ODS) safety
shutoff system shuts down the heater if not enough
fresh air is available. See
Fresh Air for Combustion
and Ventilation
, page 3.
3. Keep all air openings in heater clear, free of debris
or any blockage. This will insure that enough air for
proper combustion enters the heater.
4. If heater shuts off, do not relight until you provide
fresh, outside air. If heater keeps shutting off, it re
-
quires servicing.
5. Turn off and let cool before servicing. Only a quali
-
fied service person should service and repair heater.
6. Do not run heater:
•
Where flammable liquids or vapors are used or stored
•
During dusty conditions.
7. Before using furniture polish, wax, carpet cleaner or
similar products, turn heater off. If heated the vapors
from these products may create a white powder
residue within burner box or on adjacent walls or
furniture.
8. Do not use heater if any part has been underwater.
Immediately call a qualified service technician to in
-
spect the room heater and to replace any part of the
control system and any gas control which has been
underwater.
9. Operating heater above elevations of 4,500 feet
could cause pilot/ODS to shutdown heater.
10.Always run heater with control knob in a locked posi
-
tion. Never set control knob between locked posi
-
tions. Poor combustion and higher levels of carbon
monoxide may result if control knob is left between
locked positions.
Control Knob
Grill
Front Panel
Burners
Heater
Cabinet
SPECIFICATIONS
MHVFBI10LPT
BTU (Available)
10,000
Type of Gas
LP-Gas Only
Ignition
Piezo
Pressure Regulator Setting
10 Inches of Water
Inlet Gas Pressure (Maximum)
14 Inches of Water
Inlet Gas Pressure (Minimum)
11 Inches of Water
Burners / Orifice nozzles
1
Thermostatic Control
Yes
Clearances: inches (mm)
Top
36” (915cm)
Sides
6” (152cm)
Floor (min. to top of carpet)
2” (51cm)
Fabric / flammable objects
36” (915cm) 36” (915cm)