DCA45SSIU4F 60 HZ GENERATOR• OPERATION MANUAL — REV. #5 (02/28/20) — PAGE 35
Table 14. Inspection/Maintenance
10 Hrs.
DAILY
250 Hrs.
500 Hrs.
or Every
12 Months
3,000 Hrs.
or Every
36 Months
OTHER
Engine
Check Engine Oil and Coolant Levels
X
Check Fuel Filter/Water Separator Bowl
X
Check Air Cleaner
X
Check Air Cleaner Element
X
Check for Leaks/Hoses/Clamps
X
Check for Loosening of Parts
X
Drain Water in Fuel
X
Change Engine Oil and Oil Filter *
1
X
Clean Unit, Inside and Outside
X
Replace Fuel Filter Elements
X
Check Engine Mounts
X
Service Battery
X
Check Air Intake Hoses
X
Check Fan Belt Condition (Replace if Necessary)
X
Check Automatic Belt Tensioner
X
Check Electrical Ground Connection
X
Clean Radiator, Check Cooling System
X
Coolant Solution Analysis, Add SCAs as Required
X
Pressure Test Cooling System
X
Check Engine Speed
X
Test Thermostats
X
Test Glow Plugs
X
Flush and Refill Cooling System
2 yrs. or 2,000 hrs.
Clean Inside of Fuel Tank
1,000 hrs.
Replace Air Cleaner Elements *
3
As Required
Check Battery Acid Level
X
Drain Environmental Tank
X
Check All Hoses and Clamps
1,000 hrs.
Generator
Measure Insulation Resistance Over 3M Ohms
X
Check Rotor Rear Support Bearing
X
*
1
During initial operation of a new engine, change oil and filter between a minimum of 100 hours and a maximum of 250 hours. Service interval
depends on type of oil.
*
2
Add “Supplemental Coolant Additives” (SCAs) to recharge the engine coolant.
*
3
Replace the primary air filter element when the restriction indicator shows a vacuum of 625 mm (25 in. H
2
0).
*
4
If the blowby hose needs to be replaced, ensure that the slope of the blowby hose is at least 1/2 inch per foot, with no sags or dips that could
collect moisture and/or oil.
*
5
A
ccumulation of carbon (soot, unburned fuel) in the exhaust pipe line and muffler could cause not only system derates but also could lead to fire
incident. To destroy the soot and unburned fuel, run the unit at rated power for some period of time until the exhaust gas become mostly colorless
every 250 hours of operation time. The carbon will be easier to be generated when the unit operates at less then 40% of rated power. In this case,
perform the above procedures at a shorter interval time.
*
6
A
pplying a large load at one time to the unit when carbon deposits have accumulated in the exhaust system could produce fire/sparks which
could lead to abnormal combustion. Therefore it is recommended to
appy the load gradually
and observe the exhaust gas color (colorless)
during the process.
*
7
Fire or sparks may emit from the exhaust gas outlet during the
carbon emission accumulation check
(load). Make sure the area surrounding
the unit is free from any
flammable
material.
MAINTENANCE
Содержание WHISPERWATT DCA45SSIU4F
Страница 2: ...PAGE 2 DCA45SSIU4F 60 HZ GENERATOR OPERATION MANUAL REV 5 02 28 20 PROPOSITION 65 WARNING ...
Страница 52: ...PAGE 52 DCA45SSIU4F 60 HZ GENERATOR OPERATION MANUAL REV 5 02 28 20 CONTROLLER WIRING DIAGRAM ...
Страница 53: ...DCA45SSIU4F 60 HZ GENERATOR OPERATION MANUAL REV 5 02 28 20 PAGE 53 NOTES ...