PAGE 32 — DCA45SSIU4F 60 HZ GENERATOR • OPERATION MANUAL — REV. #5 (02/28/20)
4. The generator’s AC voltmeter (Figure 43) will display
the generator’s output in
VOLTS
.
Figure 43. Voltmeter
5. If the voltage is not within the specified tolerance, use
the voltage adjustment control knob (Figure 44) to
increase or decrease the desired voltage.
Figure 44. Voltage Adjust Control Knob
6. The ammeter (Figure 45) will indicate
zero amps
with
no load applied. When a load is applied, the ammeter
will indicate the amount of current that the load is
drawing from the generator.
Figure 45. Ammeter (No Load)
7. The
engine oil pressure gauge
(Figure 46) will
indicate the oil pressure of the engine. Under normal
operating conditions the oil pressure should be
between 35 and 65 psi (193–586 kPa).
Figure 46. Oil Pressure Gauge
8. The
coolant temperature gauge
(Figure 47) will
indicate the coolant temperature. Under normal
operating conditions the coolant temperature should
be between 180°–225°F (75°–95°C) (
Green Zone
).
INCREASE
DECREASE
PSI
OIL PRESS
0
25
50
75
100
Figure 47. Coolant Temperature Gauge
9. The
tachometer gauge
(Figure 48) will indicate the
speed of the engine when the generator is operating.
Under normal operating conditions this speed is
approximately 1,800 rpm.
Figure 48. Engine Tachometer Gauge
10. Place the
main, GFCI, and aux.
circuit breakers in the
ON
position (Figure 49).
Figure 49. Main, Aux. and GFCI
Circuit Breakers (ON)
11. Observe the generator’s ammeter (Figure 50) and
verify it reads the anticipated amount of current with
respect to the load. The ammeter will only display a
current reading if a load is in use.
Figure 50. Ammeter (Load)
12. The generator will run until manually stopped or an
abnormal condition occurs.
°F
WATER TEMP
100
140
180
220
260
RPMX10
SPEED
0
120
150
180
210
60
MAIN
CIRCUIT
BREAKER
GFCI
CIRCUIT
BREAKER
AUXILIARY
CIRCUIT
BREAKER
GENERATOR START-UP PROCEDURE (MANUAL)
Содержание WHISPERWATT DCA45SSIU4F
Страница 2: ...PAGE 2 DCA45SSIU4F 60 HZ GENERATOR OPERATION MANUAL REV 5 02 28 20 PROPOSITION 65 WARNING ...
Страница 52: ...PAGE 52 DCA45SSIU4F 60 HZ GENERATOR OPERATION MANUAL REV 5 02 28 20 CONTROLLER WIRING DIAGRAM ...
Страница 53: ...DCA45SSIU4F 60 HZ GENERATOR OPERATION MANUAL REV 5 02 28 20 PAGE 53 NOTES ...