EXTERNAL SIGNAL
– (Only functions when external interface signal with machine
tool is connected). When turned on, this feature will allow the system to run
automatically whenever an external 24vdc signal is received from the machine tool. To
enable, change the setting from 0 to 1 and press enter. The main screen will now
display “AUTO” and the function is now enabled. When the external signal is received,
the main screen will also display “SIG” indicating that it is receiving a signal to run.
FILTER ALARM
– (Optional) This feature can be used to alert the operator when the
CDR requires maintenance based on an elapsed amount of time in hours. To enable,
change the setting from 0 to 1 and press enter. The hour timer can be configured on
the following screen.
FILTER LIFE
– This will be the set amount of time that the system runs before
alarming out and flashing the red light indicating that the system requires maintenance.
Time will vary depending on application, material removal rate, pre-filtration, etc. We
recommend starting at a low time (ex 20 hours), and increasing time as needed
depending on full the system is. Enter the desired time in hours and press enter. There
is also a filter warning percentage that can be programmed on the next screen to alert
the operator that the system requires maintenance but will continue to run the system
until the total filter life expires.
FILTER WARNING
– This will be the percentage of the total “Filter Life” time that the
system will send the operator a warning message on the HMI indicating that
maintenance will be required soon. The status light will switch between green and red
flashing indicating that the system is still running but will require maintenance soon.
Once maintenance is finished, press and hold the enter button for 5 seconds to reset
the timer an
d begin running again. (Ex, if “Filter Life” is set to 100 hours, and “Filter
Warning” is set to 25%, the system will send a warning at 75 hours.)
DEFAULTS
– To revert to factory default settings, input 1234 and press enter.