22
MPSYSTEMS-M-001/06
6.4.
Low Pressure Installation
1. Mount supplied weld clamps on clean side of machine tool coolant tank, after the screens,
typically near the low pressure pumps already installed in tank;
Use open area of tank. If no opening available, use 1 1/4" conduit punch or equivalent
size hole saw.
Be sure to place inlet dip tube away from low pressure pumps present in machine tool
tank and that dip tube stays in contact with bottom of the tank. This will ensure proper
suction of coolant.
2. Run inlet & return hoses to their respected connections on unit;
Inlet & return are clearly marked on unit.
Inlet dip tube will always be longer than return dip tube.
•
If low level plate will not fit in tank, use supplied 45” pipe fitting
Use supplied hose clamps to install hoses.
Inlet & return hoses should be no longer than 15’.
Hoses must be placed below inlet of unit, to ensure proper priming of the unit.
Do not place hoses on top of unit or stand vertically.
Screen
Dirty Side
Clean Side
Inlet
Return
Содержание AK CB20
Страница 15: ...9 MPSYSTEMS M 001 06 4 2 1 Floor Layout R VR SERIES 28 36 15 24 ...
Страница 16: ...10 MPSYSTEMS M 001 06 RF16 RT VR16 VRT SERIES 15 24 38 42 ...
Страница 25: ...19 MPSYSTEMS M 001 06 6 3 3 1 R RA11 Series Control Signal Explanation ...
Страница 26: ...20 MPSYSTEMS M 001 06 6 3 3 1 1 Variable Adaptive Series Control Signal Explanation VR ...
Страница 33: ...27 MPSYSTEMS M 001 06 6 5 3 8JIC to 6JIS Fitting Explanation ...
Страница 72: ...66 MPSYSTEMS M 001 06 10 2 Relief Valve Identifier ...
Страница 76: ...70 MPSYSTEMS M 001 06 JIS JIC Fittings Example 6 3 8 JIS 6 3 8 JIC 8 1 2 JIS 8 1 2 JIC ...
Страница 77: ...71 MPSYSTEMS M 001 06 RF8 Series Flow Diagram ...
Страница 78: ...72 MPSYSTEMS M 001 06 RFC Series Flow Diagram ...
Страница 79: ...73 MPSYSTEMS M 001 06 RA11 Series Flow Diagram ...
Страница 80: ...74 MPSYSTEMS M 001 06 RT Series Flow Diagram ...
Страница 81: ...75 MPSYSTEMS M 001 06 RF16 Series Flow Diagram ...