21
MPSYSTEMS-M-001/06
6.3.3.2.
Generic Mill Applications
Typical Mill installations require 1 port and 1 alarm signal.
Locate TSP (Through Spindle) contactor in machine tool cabinet.
o
Refer to machine tool electrical drawings booklet.
Remove 3 phase power from bottom of low pressure TSP contactor.
Some machine tools require the removal of secondary TSP 3 phase power.
Wire ‘Normally Closed’ connections in
SERIES
with TSP overload circuit.
Wire ‘Normally Open’ connections in
PARALLEL
with TSP overload circuit.
Additional machine tool alarms may need to ‘jumped out’.
o
Refer to machine tool electrical drawings booklet.
6.3.3.3.
Generic Lathe Applications
Typical lathe configurations consist of wiring control signals in
SERIES
with existing low
pressure contactor along with an external M-Code. This allows for both machine tool low
pressure and high pressure pumps to be utilized.
Wiring control signals through machine tool low pressure contactor before M-Codes will ensure
the unit shuts down when machine tool goes into a hard alarm.
Wire ‘Normally Closed’ connections in
SERIES
with machine tool low pressure coolant
overload circuit contactor.
Wire ‘Normally Open’ connections in
PARALLEL
with machine tool low pressure coolant
overload circuit contactor.
Additional machine tool alarms may need to be ‘jumped out’.
o
Refer to machine tool electrical drawings booklet.
Machine tool parameters may need to be set in order to latch external M-Code functions.
Содержание AK CB20
Страница 15: ...9 MPSYSTEMS M 001 06 4 2 1 Floor Layout R VR SERIES 28 36 15 24 ...
Страница 16: ...10 MPSYSTEMS M 001 06 RF16 RT VR16 VRT SERIES 15 24 38 42 ...
Страница 25: ...19 MPSYSTEMS M 001 06 6 3 3 1 R RA11 Series Control Signal Explanation ...
Страница 26: ...20 MPSYSTEMS M 001 06 6 3 3 1 1 Variable Adaptive Series Control Signal Explanation VR ...
Страница 33: ...27 MPSYSTEMS M 001 06 6 5 3 8JIC to 6JIS Fitting Explanation ...
Страница 72: ...66 MPSYSTEMS M 001 06 10 2 Relief Valve Identifier ...
Страница 76: ...70 MPSYSTEMS M 001 06 JIS JIC Fittings Example 6 3 8 JIS 6 3 8 JIC 8 1 2 JIS 8 1 2 JIC ...
Страница 77: ...71 MPSYSTEMS M 001 06 RF8 Series Flow Diagram ...
Страница 78: ...72 MPSYSTEMS M 001 06 RFC Series Flow Diagram ...
Страница 79: ...73 MPSYSTEMS M 001 06 RA11 Series Flow Diagram ...
Страница 80: ...74 MPSYSTEMS M 001 06 RT Series Flow Diagram ...
Страница 81: ...75 MPSYSTEMS M 001 06 RF16 Series Flow Diagram ...