9.4.
Variable Pressure
Adaptive Variable Option
Standard Installation (Recommended)
Advanced Installation
No programing necessary. The unit
automatically adapts to ensure the correct
pressure is always present at the tool. Set it
and forget it. It Just Works!
The pump will increase or decrease speed to
maintain set pressure. This ensures the
pump only works as hard as needed, greatly
reducing unnecessary heat input while also
decreasing wear of pump components
.
MP SYSTEMS
standard installation is simple
and straight forward. User only needs to
install 2 wires onto stock coolant contactor,
and 2 wires onto the stock coolant overload
for alarm. THAT’S IT, the system is ready to
run. Refer to
Section:6.3.3.1.1.
Installation becomes more complicated,
requiring at least 3 extra spare M-Codes and
additional programming. Only used in special
applications that utilize fine engraving,
coolant driven, and other specialty tools.
Allows for 3 programmable pressures & 1
default pressure to be used in applications
that require finer control.
The pump will increase or decrease speed to
maintain set pressure. This ensures the
pump only works as hard as needed, greatly
reducing unnecessary heat input &
decreasing wear of pump components
Variable Pressure factory default pressures: 1000psi, 750psi, 500psi, 250psi.
Required M-Codes
4 sets for pressures
1 set per port
9.4.1.
How to Program Variable Pressure
For programmable pressure, wires 12, 13, 14, and 15 will need to be wired to M-codes. The
port AND the desired pressure will need to be fired for the lower pressure to work.
Example
: Port 1 ON= M101. Pressure 2 =M103
M101 AND M103 will need to be active for the pressure 2 setting on port 1.
For pulsing M-codes, a finish signal may be needed. Wires 16 and 17 from the MP unit will
provide a dry contact for the finish signal.
Содержание AK CB20
Страница 15: ...9 MPSYSTEMS M 001 06 4 2 1 Floor Layout R VR SERIES 28 36 15 24 ...
Страница 16: ...10 MPSYSTEMS M 001 06 RF16 RT VR16 VRT SERIES 15 24 38 42 ...
Страница 25: ...19 MPSYSTEMS M 001 06 6 3 3 1 R RA11 Series Control Signal Explanation ...
Страница 26: ...20 MPSYSTEMS M 001 06 6 3 3 1 1 Variable Adaptive Series Control Signal Explanation VR ...
Страница 33: ...27 MPSYSTEMS M 001 06 6 5 3 8JIC to 6JIS Fitting Explanation ...
Страница 72: ...66 MPSYSTEMS M 001 06 10 2 Relief Valve Identifier ...
Страница 76: ...70 MPSYSTEMS M 001 06 JIS JIC Fittings Example 6 3 8 JIS 6 3 8 JIC 8 1 2 JIS 8 1 2 JIC ...
Страница 77: ...71 MPSYSTEMS M 001 06 RF8 Series Flow Diagram ...
Страница 78: ...72 MPSYSTEMS M 001 06 RFC Series Flow Diagram ...
Страница 79: ...73 MPSYSTEMS M 001 06 RA11 Series Flow Diagram ...
Страница 80: ...74 MPSYSTEMS M 001 06 RT Series Flow Diagram ...
Страница 81: ...75 MPSYSTEMS M 001 06 RF16 Series Flow Diagram ...