9.5.
MP 1200 Mist Collector (MC)
The MP 1200 Mist Collector is used to remove unwanted mist and vapors created by spraying fluid at
high velocity in the machine tool cabinet. The MP 1200 aids in keeping unwanted mist/vapor from
entering the work environment around the machine tool. Not only does the MP 1200 keep the air in
the work place much cleaner, it has the potential to save money by recycling wasted fluid that would
have ended up in the air, back to the machine tool reservoir.
The MP 1200 consists of 3 filtering components and 1 optional post HEPA filter add-on that can be
mounted to the top of the MP 1200. The first component in the MP 1200 is the impinger (re-usable),
this component allows the unit to separate out the heavier liquid particles. The second component, a
2” thick wire mesh screen (re-usable) that aids in removing the residual heavy liquid particles. The
final and most important component of the MP 1200 is the 19” x 23” x 12” high capacity, high
efficiency filter (expendable) that brings its efficiency up to 95%.
The optional post HEPA filter (expendable) can bring efficiency to 99.7%.
9.5.1.
Control Signal Options (MC)
Please refer to MP 1200 Mist Collector installation guide, supplied with MP 1200,
for mounting & power installation instructions.
MP 1200
Control Options
Instructions
Standard Control
MP 1200 will run at set speed (dial on unit) when high pressure is active.
Once high pressure becomes de-activated MP 1200 will run at full speed
for 20 seconds, to clear remaining mist/vapor from machine tool cabinet.
MP 1200 settings can be modified through R Series PLC, please refer to
Section 7.4: Settings
.
M-Code Control
Latching M-Codes
o
MP wire #12 (ON/OFF)
o
MP wire #9 (+24VDC) common
Pulsing M-Codes
o
MP wire #12 (ON)
o
MP wire #13 (OFF)
Flood Coolant
Control
MP wire #9 (+24VDC) common
MP wire #12 (ON/OFF)
A dry contactor must be used, no other machine tool wires may be
present.
MP wire #9 on Terminal 13
MP wire #12 on Terminal 14
Refer to
Section 7.4. Settings
to modify PLC to allow for M-Code Control or Flood Coolant
control.
Wire numbers are subject to change. Please refer to AE GEN SGNL, attached to signal
harness supplied in installation kit.
Содержание AK CB20
Страница 15: ...9 MPSYSTEMS M 001 06 4 2 1 Floor Layout R VR SERIES 28 36 15 24 ...
Страница 16: ...10 MPSYSTEMS M 001 06 RF16 RT VR16 VRT SERIES 15 24 38 42 ...
Страница 25: ...19 MPSYSTEMS M 001 06 6 3 3 1 R RA11 Series Control Signal Explanation ...
Страница 26: ...20 MPSYSTEMS M 001 06 6 3 3 1 1 Variable Adaptive Series Control Signal Explanation VR ...
Страница 33: ...27 MPSYSTEMS M 001 06 6 5 3 8JIC to 6JIS Fitting Explanation ...
Страница 72: ...66 MPSYSTEMS M 001 06 10 2 Relief Valve Identifier ...
Страница 76: ...70 MPSYSTEMS M 001 06 JIS JIC Fittings Example 6 3 8 JIS 6 3 8 JIC 8 1 2 JIS 8 1 2 JIC ...
Страница 77: ...71 MPSYSTEMS M 001 06 RF8 Series Flow Diagram ...
Страница 78: ...72 MPSYSTEMS M 001 06 RFC Series Flow Diagram ...
Страница 79: ...73 MPSYSTEMS M 001 06 RA11 Series Flow Diagram ...
Страница 80: ...74 MPSYSTEMS M 001 06 RT Series Flow Diagram ...
Страница 81: ...75 MPSYSTEMS M 001 06 RF16 Series Flow Diagram ...