Installation
Dishwasher Cold Water Connection
55-75ºF / 13-24ºC
MINIMUM/MAXIMUM INCOMING
TEMPERATURE
45 PSI / 310 kPa
MINIMUM INCOMING
SUPPLY FLOWING PRESSURE
INSTALL A ¾” OR LARGER FULL PORTSHUT-OFF VALVE IN THE WATER
SUPPLY LINE AS CLOSE TO THE DISHWASHER AS POSSIBLE FOR SERVICING.
WATER HARDNESS OF 3 GRAINS/US GAL - 0.83 IMP GAL - 5.3mg/L OR LESS.
18-20 PSI / 124/138 kPa
MINIMUM/MAXIMUM
OPERATING FLOWING PRESSURE
CAUTION:
To prevent damage to the dishwasher supply valves, the installing
plumber must thoroughly flush debris from the water supply line before connecting
it to the dishwasher. Damage caused by improper installation is not covered by the
limited warranty.
COLD
WATER
INSTALL A ¾” OR LARGER FULL PORT SHUT-OFF VALVE IN THE WATER
SUPPLY LINE AS CLOSE TO THE DISHWASHER AS POSSIBLE FOR SERVICING.
WATER HARDNESS OF 3 GRAINS/US GAL - 0.83 IMP GAL - 5.3mg/L OR LESS.
Fig. 4
3/4" NPT
Cold Water
Connection
4
MINIMUM 3/4" NPT COLD WATER SUPPLY
Содержание MD2000-HR
Страница 32: ...12 11 10 14 13 9 8 7 6 5 4 1 2 3 Wash Pump Motor 24 ...
Страница 38: ...Door Lock 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 30 ...
Страница 46: ...Electrical Schematic 38 ...
Страница 47: ...39 ...
Страница 48: ...40 ...