EDS-405A/408A Series User’s Manual
Featured Functions
3-51
Using Auto Warning
Since industrial Ethernet devices are often located at remote areas of a system, these devices will
not always know what is happening elsewhere on the network. This means that an industrial
Ethernet switch that connects to these devices must provide system maintainers with real-time
warning messages. Even when control engineers are out of the control room for an extended
period of time, they can still be informed of the status of devices almost instantaneously when
exceptions occur. The EDS supports different approaches such as email and relay output to warn
engineers automatically.
Configuring Email Warning
The Auto Email Warning function uses e-mail to alert the user when certain user-configured
events take place.
Three basic steps are required to set up the Auto Warning function:
1.
Configuring Email Event Types
Select the desired
Event types
from the Console or Web Browser Event type page (a
description of each event type is given later in the
Email Warning Events setting
subsection).
2.
Configuring Email Settings
To configure the EDS’s email setup from the Console interface or browser interface, enter
your Mail Server IP/Name (IP address or name), Account Name, Account Password, Retype
New Password, and the email address(es) to which warning messages will be sent.
3.
Activate your settings and test email if necessary
After configuring and activating your EDS’s Event Types and Email Setup, you can use the
Test Email
function to see if your e-mail addresses and mail server address have been
properly configured.
Email Warning Events Settings
NOTE: The user interface for the EDS-408A shows 8 ports.