EDS-405A/408A Series User’s Manual
Featured Functions
3-30
Set as Master
Setting
Description
Factory Default
Enabled
Select this EDS as Master
Disabled
Do not select this EDS as Master
Not checked
Redundant Ports
Setting
Description
Factory Default
1st Port
Select any port of the EDS to be one of the
redundant ports.
EDS-405A: port 4
EDS-408A: port 7
2nd Port
Select any port of the EDS to be one of the
redundant ports.
EDS-405A: port 5
EDS-408A: port 8
Enable Ring Coupling
Setting
Description
Factory Default
Enable
Select this EDS as Coupler
Disable
Do not select this EDS as Coupler
Not checked
Coupling Mode
Setting
Description
Factory Default
Dual Homing
Select this item to change to the Dual
Homing configuration page
EDS-408A
Primary Port: port 5
Backup Port: port 6
EDS-405A
Primary Port: port 2
Backup Port: port 3
Ring Coupling
(backup)
Select this item to change to the Ring
Coupling (backup) configuration page
EDS-408A: Port 5
EDS-405A: Port 2
Ring Coupling
(primary)
Select this item to change to the Ring
Coupling (primary) configuration page
EDS-408A: Port 5
EDS-405A: Port 2
Primary/Backup Port
Setting
Description
Factory Default
Primary Port
Select any port of the EDS to be the
primary port.
EDS-405A: port 2
EDS-408A: port 5
Backup Port
Select any port of the EDS to be the
backup port.
EDS-405A: port 3
EDS-408A: port 6