EDS-405A/408A Series User’s Manual
Featured Functions
3-28
Coupling Port
Setting
Description
Factory Default
Coupling Port
Select any port of the EDS to be the
coupling port
EDS-405A: port 2
EDS-408A: port 5
Coupling Control Port
Setting
Description
Factory Default
Coupling Control Port
Select any port of the EDS to be the
coupling control port
EDS-405A: port 3
EDS-408A: port 6
Configuring “Turbo Ring V2”
NOTE
When using the Dual-Ring architecture, users must configure settings for both Ring 1 and Ring 2.
In this case, the status of both rings will appear under “Current Status.”
Explanation of “Current Status” Items
Now Active
Shows which communication protocol is in use:
Turbo Ring
,
Turbo Ring V2
,
Turbo Chain
,
RSTP
, or
none
.
Ring 1/2—Status
Shows
Healthy
if the ring is operating normally, and shows
Break
if the ring’s backup link is
active.