AirWorks AWK-3131-RCC
Web Console Configuration
3-24
Default gateway
Setting
Description
Factory Default
IP address of a default
gateway
The IP address of the router that connects to an outside
network
None
Subnet mask
Setting
Description
Factory Default
subnet mask
Identifies the type of sub-network (e.g., 255.255.0.0 for a
Class B network, or 255.255.255.0 for a Class C network)
None
Primary/ Secondary DNS server
Setting
Description
Factory Default
IP address of Primary/
Secondary DNS server
The IP address of the DNS Server used by your network. After
entering the DNS Server’s IP address, you can use URL as well.
The Secondary DNS server will be used if the Primary DNS
server fails to connect.
None
Start IP address
Setting
Description
Factory Default
IP address
Indicates the IP address which AWK-3131-RCC can start
assigning
None
Maximum number of users
Setting
Description
Factory Default
1 – 999
Specifies how many IP address can be assigned continuously None
Client lease time
Setting
Description
Factory Default
1 – 10 days
The lease time for which an IP address is assigned. The IP
address may go expired after the lease time is reached.
10 (days)
Packet Filters
The AWK-3131-RCC includes various filters for IP-based packets going through LAN and WLAN interfaces. You
can set these filters as a firewall to help enhance network security.
MAC Filter
The AWK-3131-RCC’s MAC filter is a policy-based filter that can allow or filter out IP-based packets with
specified MAC addresses. The AWK-3131-RCC provides 8 entities for setting MAC addresses in your filtering
policy. Remember to check the Active check box for each entity to activate the setting.
Enable
Setting
Description
Factory Default
Enable
Enables MAC filter
Disable
Disable
Disables MAC filter
www.ipc2u.ru