AirWorks AWK-3131-RCC
Getting Started
2-2
First-time Installation and Configuration
Before installing the AWK-3131-RCC, make sure that all items in the Package Checklist are in the box. You will
need access to a notebook computer or PC equipped with an Ethernet port. The AWK-3131-RCC has a default
IP address that must be used when connecting to the device for the first time.
•
Step 1: Select the power source.
The AWK-3131-RCC can be powered by a DC power input or PoE (Power over Ethernet). The
AWK-3131-RCC will use whichever power source you choose.
•
Step 2: Connect the AWK-3131-RCC to a notebook or PC.
Since the AWK-3131-RCC supports MDI/MDI-X auto-sensing, you can use either a straight-through cable or
crossover cable to connect the AWK-3131-RCC to a computer. The LED indicator on the AWK-3131-RCC’s
LAN port will light up when a connection is established.
•
Step 3: Set up the computer’s IP address.
Choose an IP address on the same subnet as the AWK-3131-RCC. Since the AWK-3131-RCC’s default IP
address is 192.168.127.253, and the subnet mask is 255.255.255.0, you should set the IP address of
the computer to 192.168.127.xxx.
NOTE
After you select Maintenance
Load Factory Default and click the Submit button, the AWK-3131-RCC
will be reset to factory default settings and the IP address will be reset to 192.168.127.253.
•
Step 4: Use the web-based manager to configure the AWK-3131-RCC
Open your computer’s web browser and type http://192.168.127.253 in the address field to access the
homepage of the web-based Network Manager. Before the homepage opens, you will need to enter the user
name and password as shown in the following figure. For first-time configuration, enter the default user
name and password and then click on the Login button:
NOTE
Default user name and password:
User Name:
admin
Password:
root
For security reasons, we strongly recommend changing the default password. To do so, select Maintenance
Password, and then follow the on-screen instructions to change the password.
NOTE
After you click Submit to apply changes the web page will refresh (Updated) will appear on the page and a
blinking reminder will be shown on the upper-right corner of the web page:
To activate the changes click Restart and then Save and Restart after you change the settings. About 30
seconds are needed for the AWK-3131-RCC to complete the reboot procedure.
www.ipc2u.ru