AirWorks AWK-3131-RCC
Web Console Configuration
3-5
IP configuration
Setting
Description
Factory Default
DHCP
The AWK-3131-RCC’s IP address will be assigned automatically
by the network’s DHCP server
Static
Static
Set up the AWK-3131-RCC’s IP address manually.
IP address
Setting
Description
Factory Default
AWK-3131-RCC’s IP
address
Identifies the AWK-3131-RCC on a TCP/IP network.
192.168.127.253
Subnet mask
Setting
Description
Factory Default
AWK-3131-RCC’s
subnet mask
Identifies the type of network to which the AWK-3131-RCC is
connected (e.g., 255.255.0.0 for a Class B network, or
255.255.255.0 for a Class C network).
255.255.255.0
Gateway
Setting
Description
Factory Default
AWK-3131-RCC’s
default gateway
The IP address of the router that connects the LAN to an outside
network.
None
Primary/ Secondary DNS server
Setting
Description
Factory Default
IP address of the
Primary/Secondary
DNS server
The IP address of the DNS Server used by your network. After
entering the DNS Server’s IP address, you can input the
AWK-3131-RCC’s URL (e.g., http://ap11.abc.com) in your
browser’s address field instead of entering the IP address. The
Secondary DNS server will be used if the Primary DNS server
fails to connect.
None
Time Settings
The AWK-3131-RCC has a time calibration function based on information from an NTP server or user specified
Date and Time information. Functions such as Auto warning can add real-time information to the message.
The Current local time shows the AWK-3131-RCC’s system time when you open this web page. You can click
on the Set Time button to activate the updated date and time parameters. An “(Updated)” string will appear
to indicate that the change is complete. Local time settings will be immediately activated in the system without
running Save and Restart.