AX34509b_e.doc / Mrz-16
Page 19 / 38
6.3.2.
Dual Mode (Inputs A and B separately)
A
B
With this mode, the SET key selects between display of channel A
and display of channel B, and the bar of the high order LED
indicates which of the two channels is actually in display.
Menu Text
Input Range
Default
Input B range
Set the desired range for input B
V/-10V
Current 0-20 mA
Current 4-20 mA
Start value B
Value which the unit will display with a
zero input signal of 0 volts or 0/4 mA
-99999 … 99999
0
End value B
Value which the unit will display with a
full scale input of 10 volts or 20 mA
-99999 … 99999
1000
Decimal point for signal B
Select the desired position of the decimal
point
000000
000000
No decimal point
00000.0
one decimal position
---->
0.00000
five decimal positions
Average filter input B
Adjustable floating average filter for
smoothing the display with unsteady input
signals
No filtering
2,4,8,16
Number of floating averaging
cycles
Offset value for input B *)
Offset value for the zero displacement of
input A signals
-99999 … 99999
0
*) When Tare function is switched on only