22

 

VMX-agility Series Quick Start Guide 
MAN-AGY-014. Version 01 28/05/2019

 

 
 
 
 

Rating Table 

 Vertically Mounted 

I

e

 

kW 

1)

 

FLA 

Hp 

2)

 

Trip Class 10 

Trip Class 20 

Trip Class 30 

3)

 

230V  400V  500V 

4)

 

3)

 

200V  208V 

220-

240V 

440-

480V 

550-

600V 

4)

 

I

e

: AC-53a:  

3.5-17: F-S

 5)

 

I

e

: AC-53a:  

4-19: F-S 

5)

 

I

e

: AC-53a:  

4-29: F-S 

5)

 

17 

7.5 

7.5 

17 

10 

15 

VMX-AGY-101 

17 

7.5 

7.5 

17 

10 

15 

VMX-AGY-101 

VMX-AGY-103 

17 

7.5 

7.5 

17 

10 

15 

VMX-AGY-101 

VMX-AGY-103 

VMX-AGY-105 

22 

5.5 

11 

11 

22 

7.5 

15 

20 

VMX-AGY-103 

VMX-AGY-105 

VMX-AGY-107 

29 

7.5 

15 

15 

27 

7.5 

7.5 

7.5 

20 

25 

VMX-AGY-105 

VMX-AGY-107 

VMX-AGY-109 

35 

7.5 

18.5 

22 

34 

10 

10 

10 

25 

30 

VMX-AGY-107 

VMX-AGY-109 

VMX-AGY-111 

41 

11 

22 

22 

41 

10 

10 

10 

30 

40 

VMX-AGY-109 

VMX-AGY-111 

VMX-AGY-113 

55 

15 

30 

37 

52 

15 

15 

15 

40 

50 

VMX-AGY-111 

VMX-AGY-113 

VMX-AGY-201 

66 

18.5 

37 

45 

65 

20 

20 

20 

50 

60 

VMX-AGY-113  

VMX-AGY-201 

VMX-AGY-203 

80 

22 

45 

55 

77 

20 

25 

25 

60 

75 

VMX-AGY-201 

VMX-AGY-203 

VMX-AGY-205 

106 

30 

55 

75 

100 

30 

30 

30 

75 

100 

VMX-AGY-203 

VMX-AGY-205 

VMX-AGY-207 

132 

37 

75 

90 

125 

40 

40 

40 

100 

125 

VMX-AGY-205 

VMX-AGY-207 

VMX-AGY-209 

160 

45 

90 

110 

156 

50 

50 

60 

125 

150 

VMX-AGY-207 

VMX-AGY-209 

VMX-AGY-301 

195 

55 

110 

132 

192 

60 

60 

60 

150 

200 

VMX-AGY-209 

VMX-AGY-301 

VMX-AGY-303 

242 

75 

132 

160 

242 

75 

75 

75 

200 

250 

VMX-AGY-301 

VMX-AGY-303 

VMX-AGY-305 

302 

90 

160 

200 

302 

100 

100 

100 

250 

300 

VMX-AGY-303 

VMX-AGY-305 

361 

110 

200 

250 

361 

125 

125 

150 

300 

350 

VMX-AGY-305 

Rating Table 

 Horizontally Mounted 

I

e

 

kW 

1)

 

FLA 

Hp 

2)

 

Trip Class 10 

Trip Class 20 

Trip Class 30 

3)

 

230V  400V  500V 

4)

 

3)

 

200V  208V 

220-

240V 

440-

480V 

550-

600V 

4)

 

I

e

: AC-53a:  

3.5-17: F-S

 5)

 

I

e

: AC-53a:  

4-19: F-S 

5)

 

I

e

: AC-53a:  

4-29: F-S 

5)

 

17 

7.5 

7.5 

17 

10 

15 

VMX-AGY-101 

VMX-AGY-103 

17 

7.5 

7.5 

17 

10 

15 

VMX-AGY-101 

VMX-AGY-103 

VMX-AGY-105 

17 

7.5 

7.5 

17 

10 

15 

VMX-AGY-103 

VMX-AGY-105 

VMX-AGY-107 

22 

5.5 

11 

11 

22 

7.5 

15 

20 

VMX-AGY-105 

VMX-AGY-107 

VMX-AGY-109 

29 

7.5 

15 

15 

27 

7.5 

7.5 

7.5 

20 

25 

VMX-AGY-107 

VMX-AGY-109 

VMX-AGY-111 

35 

7.5 

18.5 

22 

34 

10 

10 

10 

25 

30 

VMX-AGY-109 

VMX-AGY-111 

VMX-AGY-113 

41 

11 

22 

22 

41 

10 

10 

10 

30 

40 

VMX-AGY-111 

VMX-AGY-113 

 

55 

15 

30 

37 

52 

15 

15 

15 

40 

50 

VMX-AGY-113  

 

 

1)

 

Rated operational powers in kW as per IEC 60072-1 (primary series) corresponding to IEC current rating. 

2)

 

Rated operational powers in hp as per UL508 corresponding to FLA current rating. 

3)

 

The I

e

 and FLA rating applies for a maximum surrounding air temperature of 40

o

C. Above 40

o

C de-rate linearly by 2% 

of Ie or FLA per 

o

C to a maximum of 60

o

C. 

4)

 

kW and Hp ratings applicable for VMX-AGY-101-6 to VMX-AGY-305-6 models only. 

5)

 

For VMX-AGY-101 to VMX-AGY-209, duty cycle F-S = 90-5, however more cycles per hour are possible with optional 
fan fitted as indicated in Fan option table. For VMX-AGY-301 to VMX-AGY-305, duty cycle F-S = 90-3 for more cycles 
consult Motortronics UK or supplier. 

 

 

Technical Information/Specification 

 

Содержание VMX-agility

Страница 1: ...Innovation in soft start technology VMX agilityTM QUICK START GUIDE MAN AGY 014 Version 0...

Страница 2: ...ics UK deliverables including magnetic optical and or any other soft copy of these deliverables This document may not be reproduced in full or in part without written permission Enquiries about copyri...

Страница 3: ...information contained in this manual is subject to change at any time and without prior notice In no event will responsibility or liability be accepted for direct indirect or consequential damages re...

Страница 4: ...ovided if the heat output of the unit is greater than the cabinet will dissipate Theheat dissipated can be approximated with the formula Starting Watts agility start current A x start time s x number...

Страница 5: ...us injury or damage to equipment Accessories The following accessories have been developed and tested for use with the agility range of soft starts VMX AGY 012 Remote keypad for VMX AGY 101 to VMX AGY...

Страница 6: ...VMX AGY 101 to VMX AGY 113 Weight 1 97kg 3 75lb Fitting 25mm 0 98 25mm 0 98 75mm 2 95 75mm 2 95 25mm 0 98 Installation continued Air Flow inch Note VMX agility may be horizontally mounted with deratio...

Страница 7: ...0 2019 Dimensions VMX AGY 201 to VMX AGY 205 Weight 6 kg 13 22LB VMX AGY 201 to VMX AGY 207 6 3 kg 13 89 VMX AGY 209 Fitting 25mm 0 98 100mm 3 93 100mm 3 93 Installation continued inch 40mm 1 57 40mm...

Страница 8: ...AN AGY 014 Version 02 04 10 2019 Dimensions VMX AGY 301 to VMX AGY 305 Weight 15kg 33 10lb 125mm 4 92 Air Flow Installation continued 60mm 2 36 60mm 2 36 125mm 4 92 25mm 0 98 inch 13 1 332 2 4 60 6 4...

Страница 9: ...be supplied as an option for short circuit protection of the semiconductors These fuses must be fitted externally to the VMX agilityTM chassis to comply with certain standards It is the responsibility...

Страница 10: ...lectrical Connections Mains Circuit Wiring Diagram Electrical Installation continued 3 Phase Electrical Supply Connections L1 L2 L3 RJ45 connector Modbus RTU USB Connector Control Terminals AC Inducti...

Страница 11: ...Gear Provided by customer L N PE Single Phase Operation VMX agilityTM soft starts may be operated with a single phase supply and motor The base rating of the unit is unchanged Electrical Connection E...

Страница 12: ...ed 24Vdc 3 250Vac 2A Cos 0 5 Digital Input 2 D2 Selectable Functions Different functions may be assigned to Digital Input 2 in the I O menu Available assignments are Reset Hold Start Ramp Enable Fire...

Страница 13: ...dc Note 110 230V control supply possible with optional control supply module VMX AGY 021 or VMX AGY 020 for models VMX AGY 101 to VMX AGY 113 only K1 0V K2 2 24V D1 D2 13 0V COM 14 21 22 FU1 24V dc No...

Страница 14: ...rmined by the Motor Current setting and the Trip Class setting Trip class choices are Class 10 Class 20 and Class 30 The VMX agilityTM soft starters are protected using full I 2 T motor overload with...

Страница 15: ...e A flashing centre button indicates that a menu item may be selected or saved Configuration and Parameters Status messages Instantaneous motor current Control scheme Local Control terminal Modbus RTU...

Страница 16: ...Quick Start Guide MAN AGY 014 Version 02 04 10 2019 Operation Local Motor Start Example Navigation Method Auto Application Setup Configuration and Parameters continued Quick Return to Status Screen Ce...

Страница 17: ...High Inertia 40 10 0 30 3 5 60 Fan Low Inertia 30 15 0 10 3 5 30 Grinder 40 10 0 20 3 5 40 Mill 40 10 0 20 3 5 40 Mixer 10 10 0 20 4 25 Moulding M C 10 10 0 10 4 5 25 Press Flywheel 40 10 0 20 3 5 40...

Страница 18: ...pply Number of poles 3 main poles 2 main poles controlled by semiconductor switching element Rated insulation voltage Ui Main circuit See Key to part numbers Control supply circuit 230Vac r m s 1 Rate...

Страница 19: ...frequency dc Rated voltage Uc 24Vdc With VMX AGY 020 VMX AGY 021 module Control Supply Supply input L N Kind of current rated frequency ac 50 60Hz 5Hz Rated voltage Us 110V to 230Vac Rated input curr...

Страница 20: ...applies when the finger guards as supplied are fitted 7 Transient surge suppression shall be installed on the line side of this equipment and shall be rated 600_V phase to phase suitable for overvolt...

Страница 21: ...UL508 Table 6 4 and UL508A Table 15 1 Environmental Specifications Model VMX AGY 101 103 105 107 109 111 113 Frame Size 1 Heat output W 9 12 14 16 20 25 30 Weight kg lb 1 97 4 20 Model VMX AGY 201 203...

Страница 22: ...elay Fuses with a Maximum Rating of ___Z1___ or by a Circuit Breaker with a Maximum Rating of ___Z2___ 2 Correctly selected semiconductor fuses can provide additional protection against damage to the...

Страница 23: ...100 250 300 VMX AGY 303 VMX AGY 305 361 110 200 250 361 125 125 150 300 350 VMX AGY 305 Rating Table Horizontally Mounted Ie kW 1 FLA Hp 2 Trip Class 10 Trip Class 20 Trip Class 30 A 3 230V 400V 500V...

Страница 24: ...toka Spodaj opisana dela smejo izvajati samo elektrostrokovnjaki in elektrotehni no pou ene osebe Nebezpe enstvo ohrozenia ivota elektrick m pr dom Pr ce ktor s ni ie op san sm vykon vat iba elektroo...

Отзывы: