Description
68P81096E36-H
11
06/28/05
Power Supply Module Operation
Power Supply Modules are offered to handle:
•
ac or dc input power
•
low power (250 W) or high power (500 W) station requirements
A high power Power Supply Module (500 W) is used in a station with a high power Power
Amplifier Module (e.g., rated at 100 W or 75 W output power).
A low power Power Supply Module (250 W) is used in a station with a low power Power Am-
plifier Module (e.g., rated at 40 W output power), or if the station is configured as a Satellite
Receiver.
ac Input Power
The 250 W models generates the +5.1 V and +14.2 V operating voltages for the station mod-
ules.
The 500 W models generates the +5.1 V, +14.2 V, and +28 V operating voltages for the sta-
tion modules.
These modules have power factor correction and include a connection for battery backup.
Table 1. Power Supply Module Models
Model
Supplied by
Input Voltage Range
Output
Voltages
Power Factor Correction
Stations with Low Power PA
DLN6624
ASTEC
85 to 264 Vac, 47 to 63 Hz
+5.1 V and
+14.2 V
Provided internally within
power supply module.
Stations with High Power PA
DLN6622
ASTEC
85 to 264 Vac, 47 to 63 Hz
+5.1 V,
+14.2 V, and
+28 V
Provided internally within
power supply module.
Содержание MTR2000 T5544
Страница 56: ...Description THIS PAGE INTENTIONALLY LEFT BLANK 68P81096E36 H 13 06 28 05 ...
Страница 160: ...VHF Receiver Module 6 68P81096E19 B 09 30 05 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 167: ...VHF Exciter Module 6 68P81096E22 C 09 30 05 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 259: ...DLN6622 500W Power Supply Module 6 68P81011Y31 O 03 10 06 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 271: ...DLN6624 250W Power Supply Module 6 68P81011Y29 O 03 10 06 THIS PAGE INTENTIONALLY LEFT BLANK ...