Wireline Interface Board Operation
Introduction
The Wireline Interface Board (WIB) serves as the interface between the customer analog tele-
phone lines and the serial data signals of the station. WIBs are offered to handle 2-wire, 4-
wire and 8-wire configurations. In general, the WIB processes and routes all wireline audio
signals between the station and the landline equipment (such as consoles, modems, etc.).
Landline-to-station and station-to-landline audio signals are connected to the WIB via copper
pairs at the rear of the station.
Wireline Interface Board Operation
The WIB contains a PCM Codec-filter device to perform the audio digitization and reconstruc-
tion, as well as the band-limiting and smoothing required by PCM systems. Analog signals are
routed as follows:
-
Inbound analog signals are converted to digital signals and routed to the SCM as wire-
line transmit data (WL TxD).
-
Outbound PCM data signals are converted to analog signals and routed to the Line 2 out-
put.
-
A latch receives control signals from the SCM (via the SPI bus) to control the gating of
the audio signals.
For a list of the actual features supported, refer to the “Summary of Operating Features” on
page 3, or the MTR2000 System Planner.
Note
Содержание MTR2000 T5544
Страница 56: ...Description THIS PAGE INTENTIONALLY LEFT BLANK 68P81096E36 H 13 06 28 05 ...
Страница 160: ...VHF Receiver Module 6 68P81096E19 B 09 30 05 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 167: ...VHF Exciter Module 6 68P81096E22 C 09 30 05 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 259: ...DLN6622 500W Power Supply Module 6 68P81011Y31 O 03 10 06 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 271: ...DLN6624 250W Power Supply Module 6 68P81011Y29 O 03 10 06 THIS PAGE INTENTIONALLY LEFT BLANK ...