2
1.2
Electrical Maintenance - LED Indicator Checks
McIAS 1610 utilizes light emitting diode (LED) indicators on the SBC, telephony
interface and the Power Supply boards to signify specific system functions. If an LED
(other than Internal Signal Battery) on the Power Supply board is not lit, a voltage
problem exists. The board must be pulled and replaced.
McIAS 1610 LEDs are described in Table 1-1 below.
LED
LED
LED
LOCATION
COLOR
NAME
DESCRIPTION WHEN LIT
SBC
Red
FAIL
Indicates system reset. Cleared by firmware
(McIAS 1610/68)
upon successful SBC initialization.
Slot 5
Yellow
STATUS
When fully lit, the processor has halted.
Green
RUN
Indicates SBC is in operation.
Green
SCON
Indicates that the SBC is the VME BUS
system controller.
SBC
Red
FAIL
Indicates system reset. Cleared by firmware
(McIAS 1610/IP)
upon successful SBC initialization.
Slot 5
Yellow
STAT
When fully lit, the processor has halted.
Green
RUN
Indicates SBC is in operation.
Green
SCON
Indicates that the SBC is the VME BUS
system controller.
Green
LAN
Indicates that the LAN chip is enabled.
Green
+12V (LAN)
Indicates that power is available to the Ethernet
transceiver interface.
Green
SCSI
Indicates that the SCSI chip is enabled.
Green
VME
Indicates VMEbus activity.
Power Supply
FRAME
Board
Green
BATTERY
-48 volt input power. (Fuse F1 is functional.)
Slot 1
SIGNAL
Green
BATTERY
-48 volt input power. (Fuse F2 is functional.)
Green
-12v
3 LEDs to indicate the output from the
Green
+12v
Power Supply to drive the rest of the
Green
+5v
system.
Table 1-1 (Part 1)